Kohler K-11842 Series Installation And Care Manual page 19

Wall-mount valve
Hide thumbs Also See for K-11842 Series:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting (cont.)
Symptoms
Probable
Causes
3.
Constant
A. Filter is
water flow.
plugged.
B. Diaphragm
seal is
damaged or
dirty.
C. Solenoid
does not work.
4.
Sporadic
A. The faucet
water flow.
is angled
incorrectly to
deck or
misaligned
with user area.
B. The wires
are pinched or
damaged.
5.
Sensor
A. Low
flashes once
voltage.
approximately
every 2
seconds. The
product
continues to
operate.
6.
Sensor
A. Low
flashes once
voltage.
approximately
every 2
seconds. The
product does
not operate.
Kohler Co.
Recommended Action
A. Clean or replace the filter.
B. If the diaphragm is cut or torn,
order a new diaphragm assembly.
Clean or replace the diaphragm.
C. Install a new solenoid assembly.
A. Verify that the faucet is mounted
according to the installation
instructions. Ensure that the faucet
is installed in a position that is
above the rim of the sink.
B. Remove the spout and verify
that the wires are tucked inside the
spout before reassembling.
A. Replace the power supply.
A. Replace the power supply.
19
1207552-2-B