Page 1
Series 7000 & 9000 Ball Valves Series 7000 8" (DN 200) Class 150 Standard Bore Series 9000 2" – 6" (DN 50 – 150) Class 150 Full Bore Series 9000 2" – 4" (DN 50 – 100) Class 300 Full Bore Installation, Maintenance and Operating Instructions...
Page 2
IMO-270EN Table of Contents GENERAL ........3 1.1 Warning .
Page 3
IMO-270EN GENERAL MAINTENANCE This instruction manual contains important information General maintenance requires periodic observation to ensure regarding the installation, maintenance, and trou- that the valve is functioning well. Routine maintenance bleshooting of Jamesbury Series 7000 8" (DN 200) Class consists of tightening the bonnet stud nuts (18) periodically 150 Standard Bore, Series 9000 2"...
Page 4
IMO-270EN PARTS LIST ITEM PART NAME QTY. Body Body Cap Ball Stem Seat Compression Plate “T” HANDLE Stud, Body See Note 1 Stud, Bonnet NOTE 1: Hexagon Nut, Body Stud See Note 1 Hexagon Nut, Bonnet Stud Quantity of studs and nuts required: Identification Tag Size Handle...
Page 5
IMO-270EN Assembly 17. Compress the spring (33) and hold down by putting the retaining ring (34) in the groove in the stem (5). 1. Clean all valve components. 18. If the valve is to be grounded, test as follows: 2. Inspect all components for damage before reassem- a.
Page 6
IMO-270EN SERVICE KITS REPAIR KITS/SPARE PARTS We recommend that valves be directed to our service cen- For further information on spare parts and service or assis- ters for maintenance. The service centers are equipped to tance visit our web-site at www.metso.com/automation. provide rapid turn around at reasonable cost and offer a new valve warranty with all reconditioned valves.