Operating instructions
en
Wireless hand-held transmitter
5217 00
General safety instructions
This product contains button cells. Swallow-
ing button cells may cause severe internal
burns within two hours. This can be fatal.
Do not swallow batteries. Risk of burns
from hazardous materials. Immediately
seek medical attention if batteries have
been swallowed or inserted into any part
of the body.
Danger of acid burns from bursting or
leaking batteries.
Keep new and used batteries away from chil-
dren.
These instructions are part of the product
and must remain with the end customer.
Observe the commissioning order
Commissioning order for the security
system Alarm Connect:
1. Mount the alarm control unit and put it
into commission (battery and 230 V
connection).
2. Configure the project in the GPA and
transfer it to the alarm control unit
memory.
3. Install all other devices, put into
commission (insert batteries, etc.) and
check the wireless connection to the
alarm control unit.
4. After successful verification, set the
alarm control unit to operation mode.
Failure to observe the commissioning
sequence will render commissioning of the
safety system unsuccessful.
Product features
The wireless hand-held transmitter can be
used to set the security area to "Internally or
Externally armed" or to disarm the area. In
addition, irrespective of the status of the
security area, the panic alarm can be
manually triggered with the wireless hand-
held transmitter in an emergency (e. g.
aggression).
Included in delivery
1 x wireless hand-held transmitter incl.
battery
1 x operating instructions
2 x stickers with Hardware ID
Ensure the package contents are complete
and undamaged. Please see "Warranty" in
case of any defects.
Sticker with Hardware ID
The device comes with two stickers with
the Hardware ID. You can use one of the
two stickers for your site map and simply
scan the Hardware ID with an appropriate
scanner during configuration in GPA.
Required accessories
• Alarm control unit Connect
(item no. 5201 00)
Device description
6
1
5
3
1
"Disarm"
2
"Externally arm"
3
"Internally arm"
4
For panic alarm only
5
Battery compartment, rear side
(including cover and screw)
6
Status LED
Commissioning the hand-held
transmitter
Conditions for device
commissioning
The project must first be successfully
commissioned in GPA (see
"Commissioning order").
Gira Project Assistant (GPA)
The security system Alarm Connect is
configured via GPA. The following settings
are made in GPA for the wireless hand-held
transmitter:
• Assign device ID.
• Enter device name.
• Put the project into commission.
After commissioning via GPA, each new
wireless hand-held transmitter must be
manually linked to the alarm control
panel Connect.
1. Put the alarm control unit Connect in
configuration mode (remove housing
cover). The tamper alarm is triggered.
2. Briefly press the pairing button: The
status LED will flash red and the pairing
mode will be activated for 15 min. After
15 min, the pairing mode will
automatically end and the status LED
will glow a steady green.
3. Within the 15 min, on the wireless hand-
held transmitter, press and hold the keys
&
for approx. 3 s. The LED status
first flashes red and then briefly lights up
green. The alarm control unit Connect
has successfully transmitted its
hardware ID to the wireless hand-held
transmitter. The wireless hand-held
transmitter is ready to operate.
4. Put the alarm control unit Connect into
operating mode (housing cover closed)
and confirm the tamper alarm on the
wireless operating unit.
Operating the wireless hand-held
transmitter
Activate "Externally armed"
Press the
release. The status LED first flashes red and
then green. Then the
briefly: the security area is switched to
"Externally armed".
Activate "Internally armed"
Hold down the
status LED (1) first flashes red and then
green. Then the
briefly: the security area is switched to
2
"Internally armed".
4
Disarm
Hold down the
status LED first flashes red and then green.
Then the
security area is switched to "disarmed".
Manually trigger panic alarm
Keep the
(approx. 3 s). The status LED first flashes
red and then green: the alarm is tripped, and
all appropriately parametrised devices for-
ward the alarm signal.
The following message is shown in the
display of the wireless operating unit:
Ongoing panic alarm
Deactivate alarm by
PIN entry
Deactivate panic alarm
The panic alarm can only be deactivated at
the wireless operating unit by entering the
user PIN!
Reset wireless hand-held transmitter
Hold down the
(approx. 7 s) until the status LED flickers
red/green.
The wireless hand-held transmitter is now
reset and is now in the default delivery
state.
button for approx. 3 s, then
button flashes red
button (approx. 3 s). The
button flashes red
button (approx. 3 s). The
button flashes red briefly: the
&
buttons pressed
&
buttons

Advertisement

loading

Summary of Contents for Gira 5217 00

  • Page 1 (insert batteries, etc.) and the wireless operating unit by entering the check the wireless connection to the user PIN! Gira Project Assistant (GPA) alarm control unit. The security system Alarm Connect is Reset wireless hand-held transmitter 4. After successful verification, set the configured via GPA.
  • Page 2 P.O. Box 1220 environmentally-sound disposal. 42461 Radevormwald The end consumer is legally Gira Giersiepen GmbH & Co. KG hereby Phone: +49 2195 602 - 0 required to return used batteries in declares that the wireless system type item Fax: +49 2195 602 - 191 accordance with legislative no.