Kaba 1460 User Manual
Hide thumbs Also See for 1460:

Advertisement

BEYOND SECURITY
Kaba programmer 1460
User manual
EN
Doc. no.: k1evo809en-2014-04

Advertisement

Table of Contents
loading

Summary of Contents for Kaba 1460

  • Page 1 BEYOND SECURITY Kaba programmer 1460 User manual Doc. no.: k1evo809en-2014-04...
  • Page 2 GERMANY Tiverton Devon EX16 6SS www.kaba.at www.kaba.de www.kaba.co.uk This documentation may not be reproduced in any manner, or otherwise reused, without the written consent of Kaba AG. Kaba® is a registered trademark of Kaba AG. Copyright by Kaba AG 2014...
  • Page 3: Table Of Contents

    Manual settings ..........38 Kaba programmer 1460...
  • Page 4 Glossary ............44 k1evo809en-2014-04 Kaba programmer 1460...
  • Page 5: About This Document

    Kaba evolo gen- eration. 1.3 Target group This user manual is intended for qualified specialist staff and specialist staff trained by Kaba involved in the installation, commissioning and servicing of electronic components distributed by Kaba. 1.4 Supplementary documentation...
  • Page 6: Attention And Warning Symbols

    1.6 Definition of terms The user manual contains specialist terms and expres- sions specific to Kaba that are explained in the glossary on page 44. In order to simplify the user manual for the reader, the...
  • Page 7: Safety Information And The Environment

    The Programmer is only to be used and operated for its intended purpose, i.e. for the configuring and pro- gramming of Kaba actuators. Any other use is not per- mitted and can cause damage to the device. 2.2 Safety instructions For safe use of the Programmer, the following safety information is to be noted.
  • Page 8: Disposal Of Packaging

    2.3 Disposal of packaging Dispose of packaging in accordance with environmental regulations The packaging is recyclable. Please do not dispose of the packaging with household waste, instead dispose of with waste for recycling. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 9: Product Description

    User manual Product description Product description Kaba stand-alone actuators can be programmed and configured by specialist staff using the Programmer. At the same time, the Programmer is the connection (interface) between the software and the actuators. 3.1 Scope of supply...
  • Page 10: Programmer Design

    The keyboard is designed like a mobile telephone. charger connection Keys Layouts Lower case Upper case characters characters Space, 0+&_$£€¥<>=#* ., ‘ ?!\“1-()@/:; ABC2ÄÀÁÂÃÅÆÇ abc2äàáâãåæç DEF3ÈÉËÊ def3èéëê GHI4ÌÍÎÏ ghi4ìíîï JKL5 jkl5 MNO6ÖÒÓÔÕØÑ mno6öòóôõøñ PQRS7ߊ pqrs7ßš TUV8ÜÙÚÛ tuv8üùúû WXYZ9ÝŽ wxyz9ýž k1evo809en-2014-04 Kaba programmer 1460...
  • Page 11 The most important symbols are listed below: Symbols Meaning / Function Export menu (configure actuators) Import menu (read actuators) Settings menu Battery charge status Settings Programmer Data Logged in with the programming master USB interface connected Connect to the programmer Firmware Kaba programmer 1460 k1evo809en-2014-04...
  • Page 12 Product description User manual Actuator symbols Symbols Actuators General character for actuators c-lever c-lever compact Cylinder Digital cylinder Reader k1evo809en-2014-04 Kaba programmer 1460...
  • Page 13: Operation

    During operation, the display shows a variety of dif- ferent dialogue boxes with requirements and notifi- cations. Refer to the display 1. During operation of the Programmer, follow the display carefully. 2. Confirm the requirements and notifications. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 14: Navigation Keys And Enter

    Do not remove the Programmer from the ac- tuator antenna range during data transfer. Take note of the signals and Programmer dis- play. The Programmer should therefore be held with its front directly on the actuator antenna. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 15: Commissioning

    • the emergency power supply. 5.3 Programmer settings 1. Press the Settings menu key. The settings menu opens. 2. Select the Programmer menu using the navigation keys UP and DOWN and confirm using the ENTER key. The submenus are displayed. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 16 1. Open the Programmer settings menu. (See Chapter 5.3.) 2. Select the Volume submenu and press the ENTER key. 3. Change the volume using the navigation keys UP or DOWN. 4. Confirm the selected value using the ENTER key. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 17 ENTER key. 5.3.5 Setting illumination 1. Open the Programmer settings menu. (See Chapter 5.3.) 2. Select the Illumination submenu and con- firm using the ENTER key. 3. Select the lighting variant and confirm using the ENTER key. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 18 1. Open the Programmer settings menu. (See Chapter 5.3.) 2. Select the Switch-off time submenu and con- firm using the ENTER key. 3. Select Switch-off time and confirm using the ENTER key. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 19 • Checksum • Hardware Version. 5.3.10Switching off the Programmer 1. Press the on/off key. To switch off, confirm the process using the menu key (yes). The switching off process can be cancelled using the menu key (no). Kaba programmer 1460 k1evo809en-2014-04...
  • Page 20: Actuator Settings

    1. Open settings menu. (See Chapter 5.2.) 2. Log in to the actuator using Programming master. 3. Select the Beep tone submenu and confirm using the ENTER key. 4. Select Beep tone on or off and confirm using the ENTER key. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 21 3. Select Opening time in the submenu and confirm using the ENTER key. 4. Select an opening time of between 2, 4, 6, 10, 20, 30, 45 seconds and 1 minute and confirm using the ENTER key. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 22: Data Settings

    2. Log in to the actuator using Programming master. 3. Select INI reset in the submenu and confirm using the ENTER key. 4. Select yes. INI reset is performed. 5.5 Data settings The saved data on the Programmer is described below. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 23 All actuator types (firmware) that are on the Pro- grammer are displayed. 4. Select the actuator type and confirm using the ENTER key. The actuator firmware versions available for the selected actuator type are displayed. Search for the desired firmware. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 24: Eac Service Tool - Updating Firmware

    The firmware data can be downloaded onto the Pro- grammer using the EAC Service Tool. Data transfer from the auxiliary programme is set out in the Kaba EAC Service Tool user manual, document no. k1evo817. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 25: Firmware Update For V4 Actuators

    6. Select Firmware Version and confirm using the ENTER key. The firmware is transferred to the actuator. 7. Use the Programmer 1460 to transfer the con- figuration to the actuator. An OS update can also be carried out for LEGIC advant components during the firmware up- date.
  • Page 26: Crossgrade For Legic Advant Components

    9. Use the Programmer 1364 to transfer the con- figuration to the actuator. 5.9 Crossgrade for LEGIC advant components It is possible to use a downgrade to make Kaba elolegic components from E300 stand-alone components. These components can therefore be used as Kaba elo- legic N-line (N300), T-line (T300) or U-line (U300).
  • Page 27 User manual Commissioning 5.9.1 Downgrade E300 (V4) to V3 The downgrade can only be carried out on Kaba stand- alone actuators. The Programmer 1460 and the Programmer 1364 are needed for the downgrade. After the downgrade, the actuator can only be programmed with the Programmer 1364.
  • Page 28 5.9.2 Upgrade V3 to E300 (V4) Check the Programmer's firmware version be- fore the actuators' firmware update and up- date the firmware if required. The upgrade can only be carried out on Kaba evolo stand-alone actuators. Start actuator in bootloader. 1. c-lever: Short-circuit the INI reset contacts on the actuator (10 s).
  • Page 29 Present master medium to the Programmer Present master medium or authorised user medium (Difference: Before the INI reset for V4 or during the INI reset for V3.) Turn DIP switch 6 ON Not for V3 actuators Kaba programmer 1460 k1evo809en-2014-04...
  • Page 30 Remote reader  Compact reader  Key: Present master medium or authorised user medium (Difference: Before the INI reset for V4 or during the INI reset for V3.) Turn DIP switches 5+6 ON Not for online actuators k1evo809en-2014-04 Kaba programmer 1460...
  • Page 31 User manual Commissioning 5.10 Crossgrade Kaba remote reader and Kaba compact reader The crossgrade variants for the Kaba reader are shown in the following table. The products can be used in var- ious function types and system solutions. The func- tions can differ in each function type.
  • Page 32 2. Select Emergency power supply in the sub- menu and confirm using the ENTER key. 3. Connect the programming cable and press the ENTER key. 4. The Programmer action is displayed. Present an authorised medium. Replace the batteries. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 33: Programming

    This chapter exclusively outlines the configuration and programming of actuators using the Programmer. Data transfer from the KEM software is described in the Kaba evolo Manager user manual, document no. k1evo806. 6.1 Main functions The two main functions that can be executed on the...
  • Page 34: Importing From Actuators

    Traceback is imported. • Configuration: All configuration data is imported (without Traceback data). • Diagnostic data: Creates a ZIP file with the memory content of the actuator. Auxiliary agent for problem solution in support cases. (See Chapter 6.3.2) k1evo809en-2014-04 Kaba programmer 1460...
  • Page 35 6.3.2 Diagnostic data Diagnostic data may also be exported from the actua- tors in this menu. 1. Connect the Programmer 1460 and the actua- tor with the programming cable. 2. Press Import menu key. 3. Log in to the actuator using Programming master.
  • Page 36 3. Connect Programmer to TouchGo actuator. 4. Navigate to the UID, SNR and RSSI points in the menu using the DOWN navigation key. 5. Press the middle menu key and touch the door handle, the measurement starts. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 37 TouchGo to function fully. The RSSI value displays the total signal strength re- ceived. High RSSI values indicate sources of interfer- ence in the immediate vicinity and reduce the functionality of TouchGo. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 38: Manual Settings

    ENTER key. The configuration of the actuator will be read out and confirmed. 6.4 Manual settings The basic settings on the actuators are implemented using the Programmer in the Settings/Actuator menu. See Chapter 5.4. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 39: Data Transfer

    2. Open File/Driver/Programmer1460. 3. Select the Install file and start. 4. Follow the installation instructions on the PC screen. 5. Connect the Programmer to the PC using the USB cable. 6. The Programmer installs itself autono- mously. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 40: Downloading Of Data From The Software

    Programmer. After installation of the drivers, the Programmer can be used with the desired software (e.g. KEM, Kaba ex- os, etc.). Please refer to the software operating manual for a detailed description of software installation.
  • Page 41: Actuator Settings

    3. Connect the Programmer to the PC using the USB cable. See chapter 7.1 on page 39 with regard to this. The date and time of the connected Program- mer are automatically adjusted after the soft- ware is started. Kaba programmer 1460 k1evo809en-2014-04...
  • Page 42: Maintenance And Troubleshooting

    1. Connect the Programmer to the mains adapter using the USB cable. 2. Plug the mains adapter into a plug socket. 3. The Programmer switches on automatically. 4. The Programmer charges the battery autono- mously if it is connected to the mains adapter. k1evo809en-2014-04 Kaba programmer 1460...
  • Page 43: Menu Structure

    Actuator firmware Technologies Memory info Actuator type Delete all Firmware version Back Programmer Language Contrast Volume Date/time Backlight Key click Turn-off timeout Name Info Back Firmware update Firmware version Function type Firmware version Emergency charge Back Kaba programmer 1460 k1evo809en-2014-04...
  • Page 44: Glossary

    Programmer onto the actuators. Kaba evolo Manager Kaba evolo Manager is software to Stand-alone configure and manage various types of The term stand-alone refers to all actu- actuators in one or more locking sys- ators which are installed independent- tems.

Table of Contents