d. On the touch screen, press the [Start] button on the [Cleaning Wipe] screen.
The feed/eject rollers rotate a certain amount simultaneously.
If you press and hold the [Start] button, the feed/eject rollers rotate continuously.
Be careful not to touch the rollers with your hand while they are rotating.
e. Put a piece of cloth moistened with Cleaner F1 or a sheet of Cleaning Wipe against the surface of the
rotating feed/eject roller, and wipe horizontally to clean dirt and dust off the whole surface.
Make sure that it is wiped properly because black residue on the rollers will affect the feeding
performance.
4. Close the ADF.
Be careful not to get your fingers caught when closing the ADF.
ATTENTION
Confirm that the ADF is closed properly. Otherwise, documents may not be fed into the ADF.
5. Clear the sheet counter after cleaning.
a.
On the touch screen, press
b.
On the [Consumable counters] screen, press the [Clear] button for [After cleaning].
-> [Cleaning & Maintenance] -> [Consumable counters].