olympia electronics GR-415/4P Quick Manual

3d light self testing maintained emergency luminaires

Advertisement

Quick Links

3D LIGHT SELF TESTING MAINTAINED EMERGENCY LUMINAIRES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)
BATTERY PROTECTION
INDICATIONS
- CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION (230V AC / emergency)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
These luminaires are used indoors (ta 40 C)
where emergency light is needed. Each luminaire
must be permanently connected to mains power
supply. In normal operation (L1 connected to L)
the led strip lights and the battery is charging. In
case of a mains power
luminaire will light the led strip automatically in
emergency mode (powered by its battery). When
the mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions on page 2.
OPERATION
Battery Charging
The battery charging is completely controlled. In
this case, the best possible battery maintenance
is achieved, as well as the elongation of its
duration. When the battery has completely
charged, it charges with a maintenance current.
Battery Cut-off
The luminaire enters in this operation when the
mains power supply fails and battery has lost its
energy. During this operation the luminaire enters
the idle state and
battery consumption is negligible, in order to be
protected from deep discharge.
Manual Test
The manual test can be conducted only if the main
Page 1 from 3
Charge, Lamp Fault, Battery Fault indication LED, TEST Button
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, EN 1838
Thank you for your trust in our products
Olympia Electronics - European manufacturer
supply failure
the
(for LED MODULE Specs. see page 3)
GR-415/4P
220-240V AC/50-60Hz
11VA
4.8V/1.5Ah
From overcharge and deep discharge
90min
4 power LEDs
460lm / 460lm
5 to 40 C
Up to 95%
ABS/PC, PC
320 x 310 x 310 mm
2820gr.
3 years (1 year for the battery)
power supply and the battery is connected. By
o
pressing the test button briefly an operation test is
initiated. During this test period all indication LEDs
are OFF.
Automatic Operational Test
This test includes all the operations that provide
the manual test and is conducted automatically
every 15 days. In order to be performed, the main
power supply and the battery should be
connected.
Automatic Autonomous Test
The Automatic Autonomous Test is conducted and
measures the luminaire`s back up operation. This
test is conducted automatically every six months.
In order to be performed, the main power supply
and the battery should be connected (the battery
should be charged). If the battery is not charged,
the test is postponed until the battery is
completely charged. If during the Automatic
Autonomous Test the luminaire's duration is lower
than the nominal, then the battery must be
replaced.
Back Up Operation
The autonomous duration of battery during
emergency mode is at least the one that is stated
in the technical characteristics. During emergency
mode, a LED strip test is also performed.
Resetting Errors
Push the Test button for 10 seconds, to delete all
the indicated LED errors.
enters regular operation mode.
GR-416/4P
14VA
4.8V/3Ah
24h
180min
IP40
o
2900gr.
Then the luminaire
923416001_09_008

Advertisement

loading

Summary of Contents for olympia electronics GR-415/4P

  • Page 1 2900gr. GUARANTEE 3 years (1 year for the battery) Thank you for your trust in our products Olympia Electronics - European manufacturer GENERAL power supply and the battery is connected. By pressing the test button briefly an operation test is These luminaires are used indoors (ta 40 C) where emergency light is needed.
  • Page 2 Indication LED status (with connected mains ΑΤΤΕΝΤΙΟΝ!!! power supply). 1. Operations for installation, maintainance or Charge testing must be done by authorized personnel On: Good charge current. only. Οff: No battery (No charging current 2. The device must be connected to the mains or disconnected battery).
  • Page 3 Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies each product. This warranty ceases to exist if the buyer does not follow the...

This manual is also suitable for:

Gr-416/4p