Installer Confi Guration Menu - White Rodgers 1F97-0671 Installation And Operating Instructions Manual

Blue residential non-programmable thermostat with automatic heat/cool changeover option for single stage applications
Table of Contents

Advertisement

INSTALLER/CONFIGURATION MENU
Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press
MENU
PRESS
DISPLAYED
REF.
BUTTON
(FACTORY DE-
FAULT)
1
MENU
(GAS)
2
MENU
CS (3)
3
MENU
E (On)
4
MENU
CR Heat (ME)
5
MENU
CR Cool (ME)
6
MENU
CL (OFF)
7
MENU
Cool Off, Heat Auto
8
MENU
dL (On)
9
MENU
(current temperature)
10
MENU
11
MENU
(On) b
12
MENU
P (7)
13
MENU
PS (4)
14
MENU
Heat AS (On)
15
MENU
Cool AS (On)
16
MENU
Remote (OFF)
MENU
Remote
MENU
Indoor Loc
(On)
17
MENU
dS (On)
18
MENU
(OFF)
Keypad Lockout
MENU
(000)
Keypad Lockout
19
MENU
L Heat
(99)
20
MENU
L Cool
(45)
or
to change a menu item options.
INSTALLER/CONFIGURATION MENU
Press
or
select from listed op-
tions
ELE
0, 1, 2, 4, 5, 6
OFF
SL, FA
SL, FA
CL On
Heat Auto Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
dL OFF
0
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
°F
°C
OFF
3, 0
2
OFF
OFF
On
Outdoor
(In)
OFF
Off
L, P, Limit
1-999
L 62 to L 98
L 46 to L 82
COMMENTS
to
GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 disables feature
Selects Energy Management Recovery (EMR)
On or OFF.
Adjustable Anticipation:
Selects heating cycle rate for MS or SS in #1 only
Adjustable Anticipation:
Selects the cycle rate for cooling
Compressor Lockout Time
System Mode Confi guration
with Automatic Changeover capability
Selects Display Light On or OFF
Adjustable Ambient Temperature Display
Selects Fahrenheit/Celsius Temperature Display
May select Beeper OFF to stop audible
key feedback
Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models.
Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
Automatic Schedule for heat mode
Automatic Schedule for cool mode
Selects Remote Sensor On/OFF
Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
Selects Local Sensor (in thermostat) to OFF.
N/A if Remote is selected to Outdoor
Selects Automatic Daylight Saving Time option
Selects one of 3 Keypad Lockout confi gurations
L - Total Keypad Lockout
P - Partial Keypad Lockout
(Up and Keys still work)
Limit - Limited Temperature RANGE
Selects personal lockout code. 000 is NOT A
VALID CODE.
Selects Limited HEAT Range Temperature
Selects Limited COOL Range Temperature
5