Extreme Networks ExtremeCloud Appliance E3120 Installation Manual page 10

Hide thumbs Also See for ExtremeCloud Appliance E3120:
Table of Contents

Advertisement

Table 3: System LED patterns
LED Pattern
Solid green
1 Hz blinking green
1 Hz blinking amber
ExtremeCloud™ Appliance E3120
System Status
Ok
Issues with the system
Fatal or unrecoverable system
hardware failure
Overview
Description
Indicates that the system is normally
running without any errors.
Indicates that:
There might be redundancy loss
in the power supply or fan.
The non-critical threshold has
crossed due to temperature,
input power to power supply,
voltage, output current for main
power rail from power supply,
and process thermal control
sensors.
Power supply failure may have
occurred while redundant power
supply was present.
There is a fault in the hard drive.
The appliance is unable to use all
of the installed memory.
The battery has failed.
Amber color means there has been a
fatal error in the system. System
failure is caused when:
Crtical threshold is crossed.
Minimum number of fans to cool
the system is not present or the
fans have failed.
The required number of power
supply is not present in the
system.
10