Download Print this page

UPO E5070W Manual page 13

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
ENGLISH / ENGLISH
specify a greater distance, this must be adhered
to.
ELECTRICAL CONNECTION
The mains power supply must correspond to the
rating indicated on the plate situated inside the
hood. If provided with a plug connect the hood
to a socket in compliance with current regula-
tions and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains
connection) or if the plug is not located in an ac-
cessible area, after installation, apply a double
pole switch in accordance with standards which
assures the complete disconnection of the mains
under conditions relating to over-current catego-
ry III, in accordance with installation instructions.
Warning! Before re-connecting the hood circuit
to the mains supply and checking the efficient
function, always check that the mains cable is
correctly assembled.
The hood is provided with a special power cable ;
if the cable is damaged, request a new one from
Technical Service.
MOUNTING
Very heavy product; hood handling and installa-
tion must be carried out by at least two persons.
Before beginning installation:
• Check that the product purchased is of a suita-
ble size for the chosen installation area.
• Remove the charcoal (*) filter/s if supplied (see
also relative paragraph). This/these is/are to
be mounted only if you want lo use the hood in
the filtering version.
• Check (for transport reasons) that there is no
other supplied material inside the hood (e.g.
packets with screws (*), guarantees (*), etc.),
eventually removing them and keeping them.
• If possible, disconnect and move freestand-
ing or slide-in range from cabinet opening to
provide easier access to rear wall/ceiling. Oth-
erwise put a thick, protective covering over
countertop, cooktop or range to protect from
damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a
protective covering and place all canopy hood
parts and hardware in it.
• In addition check whether near the installation
area of the hood (in the area accessible also
with the hood mounted) an electric socket is
available and it is possible to connect a fumes
discharge device to the outside (only suction
version).
• Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole
for the passage of the discharge tube).
Expansion wall plugs are provided to secure the
hood to most types of walls/ceilings. However, a
qualified technician must verify suitability of the
materials in accordance with the type of wall/
ceiling. The wall/ceiling must be strong enough
to take the weight of the hood. Do not tile, grout
or silicone this appliance to the wall. Surface
mounting only.
OPERATION
Use the high suction speed in cases of concen-
trated kitchen vapours. It is recommended that
the cooker hood suction is switched on for 5 min-
utes prior to cooking and to leave in operation
during cooking and for another 15 minutes ap-
proximately after terminating cooking.
1
1. Speed 1/OFF switch
2. 2, 3-speed selection
3. ON/OFF light switch
MAINTENANCE
ATTENTION! Before performing any mainte-
nance operation, isolate the hood from the elec-
trical supply by switching off at the connector and
removing the connector fuse.
Or if the appliance has been connected through a
plug and socket, then the plug must be removed
from the socket.