4.10. Review Serial Number
Command: <STX><R><4Eh><ETX><CheckSum>
This command gets the device serial number.
4.11. Message Formatting Selections (Only for Security Level 1 & 2)
4.11.1. Terminator Setting
Terminator characters are used to end a string of data in some applications.
Command: <STX><S><21h><01h><Terminator Settings><ETX><CheckSum>
<Terminator Settings>: Any one character, 00h is none; default is CR (0Dh).
4.11.2. Preamble Setting
Characters can be added to the beginning of a string of data. These can be special characters for
identifying a specific reading station, to format a message header expected by the receiving host, or
any other character string. Up to fifteen ASCII characters can be defined.
Command: <STX><S><D2h><Len><Preamble><ETX><CheckSum>
Where:
<Len>= the number of bytes of preamble string
<Preamble> = {string length}{string}
NOTE: String length is one byte, maximum fifteen <0Fh>.
4.11.3. Postamble Setting
The postamble serves the same purpose as the preamble, except it is added to the end of the data
string, after any terminator characters.
Command: <STX><S><D3h><Len><Postamble><ETX><CheckSum>
Where:
<Len> = the number of bytes of postamble string
<Postamble> = {string length}{string}
NOTE: String length is one byte, maximum fifteen <0Fh>.