Download Print this page

Maintenance - Bosch FERION 5000 OW Manual

Wireless smoke alarm
Hide thumbs Also See for FERION 5000 OW:

Advertisement

12
en | Graphics
2. Press and hold the button for about 4 s. -> The LED lights up
red (repeater function off) or green (repeater function on) for
30 s. To change the mode of the repeater function press and
release the button (< 2 s). -> LED changes the color promptly.
After 30 s the device will switch to normal mode again.
Adding devices to an existing network
Perform Connecting devices, page 10 for one device of the
existing network and the unprogrammed device. (Up to 40
devices can be interconnected.)
Disconnecting a device (Reset)
For disconnecting a device you restore the factory settings. The
device will continue to work, but it will not be connected any
longer with other devices.
If the device is in normal mode (head and base assembled, no
optical signal) press and hold the button more than 10 s. ->
LED flashes first orange (connecting), then red (reset). After
releasing the button the LED changes from red, green to
orange (LED test).

5 Maintenance

Functional check
A visual inspection and a functional check must be done for each
device monthly. After the functional check the device is muted
for 10 min, even when an alarm will be triggered.
08.15 | 2.1 | F.01U.309.850