Start-Up Procedure - Canature BNT65 Series Operation Manual

Table of Contents

Advertisement

BNT65 Series Valve Operation Manual
BNT65 Series Dimensional Drawing (unit: inch, mm in brackets)

Start-up Procedure

1. Turn the knob and index the control into the Backwash position. Place the bypass
in the Service position and let water flow into the mineral tank. Allow water to run
to drain for 3-4 minutes or until all media fines are washed out of the softener or
filter.
NOTE: Manually dial the various regeneration positions by turning the knob on
the front of the control until the indicator shows that the softener is in the desired
position. For backwash filters ignore steps 3 to 5 and 7 to 9.
2. Manually index the control back to the Service position and open a softened water tap
until all air is released from the lines. Then close the tap.
3. Remove back cover plate.
4. Make sure that the salt dosage is set as recommended by the manufacturer. If necessary,
set salt according to the setting instruction sheet. Manually index the control to the Brine
Fill position and allow the brine tank to fill to the top of the air check.
5. Manually index the control to the Brine Fill position and allow the control to draw water
from the brine tank until it stops.
6. Plug in the electrical cord and look in the sight hole in the back of the motor to see that it
is running.
7. To set time of day press red time set button and turn 24-hour gear until present time of
day is at "time of day."
8. Timer Settings (Filter or Softener)
Set the regeneration days is to occur by sliding tabs on skipper wheel outward to expose
trip fingers.
Each tab is one day.