Temperature And Pressure Ranges; Filters; Technical Residue - Hardi COMMANDER 4500 Instruction Book

Twin force
Hide thumbs Also See for COMMANDER 4500:
Table of Contents

Advertisement

8 - Technical Specifications
Voltage
The sprayer is designed for the following voltage only:
Voltage
12 V DC. Tolerance: -1.5/+3.0 V DC.
Tolerance for voltage
- 1.5 V / + 3.0 V
Current from tractor
40 A peak
Blade fuses on the sprayer 25 A *
* The blade fuses usually allow up to 50 A for a few seconds before blowing.
DANGER! If the tolerances for voltage are exceeded, the electrical system can fail. Risk of fire. Risk of defect or
malfunctioning components.
Power Consumption
Recommended tractor engine output are as follows.
Main tank volume (liters)
4500
5500
7000

Temperature and Pressure Ranges

Spray Liquid System
Operating temperature range
Operating pressure for the safety valve
Max. pressure on the pressure manifold
Max. pressure on the suction manifold

Filters

The higher the number of mesh, the finer the filtration.
Size of openings in
Mesh
the filter
18
1.00 mm
30
0.58 mm
50
0.30 mm
80
0.18 mm
100
0.15 mm
*depending on selected nozzles

Technical Residue

Residue in the dilutable volume is mentioned in the table below.
The non-dilutable volume varies depending on the boom width and installed options in the fluid system. Worst case
technical residue for the sprayer with the largest tank, largest fluid system and widest spray boom is stated below. Smaller
booms and fluid systems with less options will have less residue.
Main tank: 7000 liters
FlexCapacity pump
152
Output (hp)
Output (kW)
175
130
190
140
210
160
36 - 104° F (2 - 40° C)
215 psi (15 bar)
290 psi (20 bar)
22 psi (1.5 bar)
Color
EasyClean
White
-
Green
Yes
Blue
Yes
Red
Yes
Yellow
-
18 gallons (69 liters)
10.5
Filter name / position
Cyclone
In-Line
Tank strainer
-
-
-
-
-
Yes*
Yes
Yes*
-
Yes*
12
15.0
Nozzle
Yes
-
-
-
-
Yes*
-
Yes*
-
Yes*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander 5500Commander 7000

Table of Contents