Download Print this page

AgSense Crop Link Lite Wiring Instructions

2017-18 4-20ma inputs and scaled voltage inputs
Hide thumbs Also See for Crop Link Lite:

Advertisement

Quick Links

WIRING INSTRUCTIONS
2017-18
Crop Link Lite/Pro
4-20mA INPUTS
and
SCALED VOLTAGE INPUTS

Advertisement

loading
Need help?

Need help?

Do you have a question about the Crop Link Lite and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AgSense Crop Link Lite

  • Page 1 WIRING INSTRUCTIONS 2017-18 Crop Link Lite/Pro 4-20mA INPUTS SCALED VOLTAGE INPUTS...
  • Page 3 Items Covered In This Manual: Page 1: Crop Link Device Overview Page 2: Connecting DC Power/Solar Panel Page 3: Connecting 120v AC Power Page 4: Generic 4-20mA Sensor Wiring Page 5: Scaled Voltage Input Wiring Page 6-7: Specs and Warranty Information...
  • Page 4 General Overview of the Crop Link Unit Note: Once all sensors are connected and unit is ready to run, contact your AgSense Dealer to finish setup, and configure this unit to read the sensors that you have installed.
  • Page 5 Page 1 Wiring the DC Power or Solar Panel to the Crop Link Unit Wiring the solar panel or 7-30v DC power Source: Find the last two terminals on the large terminal strip labeled DC/SOL and GND 1. Connect the Black or Negative Wire (-) from the solar panel to the terminal marked GND as shown above.
  • Page 6 If you are not using DC power or Solar Power: how to wire 120v AC to the Crop Link. 1. Connect 120v AC to the terminal marked 120v – units pre-wired with a cable from AgSense use a Black wire. Cable added by the customer should use the Black wire here.
  • Page 7 Generic 4-20mA Sensor Wiring: 1. Wire colors likely will be different in your application, please compare your sensor colors to the sensor functions listed below, and do not solely rely on the colors shown above! 2. 4-20mA Sensor must be 12v compatible. 3.
  • Page 8 Scaled Voltage Input Wiring 1. Wire colors likely will be different in your application, please compare your sensor colors to the sensor functions listed below, and do not solely rely on the colors shown above! 2. The sensor or voltage source connected must not exceed 6v DC Max! 3.
  • Page 9 Open Circuit Voltage 21.2v DC Short Circuit Current 0.69A Warranty Information: All warranty service provided by the AgSense service center, or an authorized technician. Warranty repairs require a Return Merchandise Authorization Number (RMA); Have your dealer contact AgSense to obtain this RMA number.
  • Page 10 Commander/Crop Link/Aqua Trac relies upon GPS, Satellite and Internet technology which not always functions properly, accordingly, AgSense disclaims any and all responsibility for the reliability of this technology. Customer acknowledges that AgSense does not have the ability to control the reliability of GPS, Satellite and Internet Technology. AgSense specifically disclaims any and all liability for Customer's failure to personally determine whether or not the irrigation equipment that belongs to Customer is functioning properly.
  • Page 12 AgSense, LLC 259 Dakota Ave S PO Box 53 Huron, SD 57350 605-352-8350 www.AgSense.net...

This manual is also suitable for: