Page 3
National Regulations. If the chimney has previously been used to burn solid fuel, the chimney should be swept before the stove is installed. Before the stove is installed a flue test in accordance with National Regulations should be carried out. The gas connection must be in accordance with National Regulations.
Page 4
4. Installation Install the stove in accordance with the requirements given below. If a concealed gas connection is to be made prepare the pipework prior to installing the stove. (i) SITING THE STOVE The stove can be installed in any adequate area suitable for solid fuel fires and stoves.
Page 5
(iv) FLUE CONNECTION The flue should be at least 3m high and at least 125mm diameter or equivalent area. Horizontal or negative gradients in the flue pipe should be avoided. It is recommended that a minimum height of 500mm from the stove should be established before any significant change in the direction of the flue.
Page 6
5 positioning of the logs Slacken the Allen screw using an Allen key securing the stove door and open the door (as shown below)
Page 7
Close the stove door and secure with an Allen key. Under no circumstances should the stove be operated with the door open, without the door attached or the glass damaged.
Page 8
6 Commissioning the stove When lighting the pilot follow these instructions exactly. Lighting instructions Should the stove be extinguished for any reason wait 3 minutes before re-ignition is attempted. Slacken the rear pressure test sealing screw on the left hand side of the gas valve (fig 6) and connect a suitable pressure gauge to the pressure test point.
Page 9
Adjusting the flame Height (fig 6) To turn the stove on and/or to increase the flame height, press the ▲ button and the small button A at the same time on the remote handset. Continue pressing until the desired flame height is obtained. Press and hold the ▼ button to reverse the procedure.
Page 10
Figure 6 Control Valve and transmitter Note It is recommended to turn the combination control either to the off or pilot position if the appliance is left unattended for long periods (eg away on holiday), so that it cannot receive commands from the remote transmitter.
Page 11
Stress that no extra coals or logs must be added over and above those supplied with the appliance and that any replacements must only be authorised Firebelly spares. Recommend that the stove is regularly serviced and the flue system checked by qualified persons.
Page 12
9 servicing instructions The stove is fitted with a pilot light and flame sensing device which is also an oxygen depletion sensor (O.D.S) This system is not adjustable and must not be put out of action. If any parts of this system require replacement only original manufacturers parts must be used.