8.4

Cooling water

8.4.1

Quality of cooling water

Distilled water causes immediate corrosion on bare parts, which is often unno-
ticeable at first, but later leads to serious corrosion damage.
Ü
Do not use pure or distilled water.
Deposits in cooling channels due to unsuitable cooling water prevent the dis-
sipation of heat.
Ü
Use cooling water with the following properties:
Drinking water
Hardness
PH value
Additive (corrosion protection)
8.4.2

Setting the cooling

Ü
Observe the following values for liquid cooling:
Hose diameter (*)
Feed temperature
Volumetric flow
Return temperature
(*) Use cooling hoses that are impermeable to UV light.
Installation
according to
98/83/EC
1-15°dH
7-9
20% Antifrogen N
Min. DN 5.5
Min. 20°C
Min. 1.5 l/min
Max. 40°C