of the DC Control box and route the 14-gauge conductor wire through the hole. Attach the momentary ON power switch using the four (4) screws in the
switch plate. Replace DC Control box cover removed in Step 4. Remember to re-connect the 12vDC power source that you disconnected at the start
of Step 4.
4 POST DC WIRING CONFIGURATION
12v DC
(+) & (-)
14awg
Enable Switch
SPST
Normally Open
Momentary
18awg
TO EXTEND THE POWER CORD:
Pull out sufficient cord length that will allow you to route shore
power cord to the electrical distribution box and plug the molded
end into the receptacle.
MAINTENANCE
• Experience has shown that when only a short section of the power cable is regularly used, the cable may be subject to "kinking". To relieve this con-
dition, routinely extend the power cable completely and stretch it on any smooth surface. Allow the Cablemaster™ to then retract the cable onto the
reel.
• At least once a year, inspect all AC and DC wiring connections and make sure they are free of corrosion.
• Periodically inspect the exterior jacket of the power cable for nicks or cuts.
• If your power cable is dirty any cleaner should be compatible with the outer jacket material of the power cable.
• If needing to replace power cordset USE ONLY 105ºC RATED CORDSETS.
DC WIRING DIAGRAM
DC Control Panel
DC (-) 12v
DC (+) 12v
Enable Sw. 2
Enable Sw. 1
OPERATION INSTRUCTIONS
5 POST DC WIRING CONFIGURATION
N.C.
N.C.
6
3
C
C
5
2
N.O.
N.O.
4
1
Black - 12v DC (-)
Red - 12v DC (+)
DC hookup wire:
Green - NC - Micro Switch
14awg
Blue - NO - Motor 2
White - NO - Motor 1
TO RETRACT THE POWER CORD:
Press and hold the button and the power cord will automatically
retract (CAUTION — it is advisable to monitor the progress of
the power cord as it retracts and stores onto the reel).
DPST Control Switch
- No Center Position
- Momentary
12v DC
(+) & (-)