Synergis IX DIN Rail Single Door Controller SY-SIX-CTRL-DIN-1D Installation Manual...
Page 2
In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instructions found in this document or the computer software and hardware products described herein.
Door Access Control ......................22 Reader Location ............................22 RS-485 Card Reader Connection (Entry Only) ..................22 RS-485 Card Reader Connection (Entry/Exit) .................... 23 SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 4
New Zealand and Australia ....................38 European Standards ......................39 FCC Compliance Statements ....................41 Industry Canada Statement ....................42 SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Introduction The Synergis IX DIN Rail Single Door Controller is the central processing unit of the Synergis System. It communicates with all system modules, stores all configuration and transaction information, processes all system communication, and reports alarms and system activity to a monitoring station or remote computer.
A single-point earth ground connection avoids the creation of ground loops in the system and provides a single reference point to earth ground. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 7
Note that the DIN Rail enclosure earth terminal is connected to the power supply V- terminal. There must be only one single earth grounding point per system. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Insert a flat blade screwdriver into the hole in the tab at the top of the Controller. Lever the tab up and rotate the unit off the DIN Rail mount. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Example 2A Power Supply Connection: Power Supply Controller V2+ V- To other modules on network AC AC Transformer Mains Input Gel Cell Backup Batteries SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 10
Example Multiple PSU Connection: Module #2 Module #3 Module #1 Controller Power Supply #3 Power Supply #2 Power Supply #1 SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
When using a PoE Router as power source for the Controller, the rating for the auxiliary outputs (S- S+) will be different to those when the Controller is being powered by an Genetec Power Supply or a 12V DC supply. Please refer to the values outlined in the Technical Specifications (see page 37) for more details.
CAT5e / CAT6 are also supported for data transmission when using ground in the same cable (to a maximum length 100m (328ft)) Warning: Unused wires in the cable must not be used to carry power to other devices. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Battery fault conditions will activate the battery trouble zone associated with the address assigned to the Controller. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
SB SA S- S+ Z2 V- Z1 NC C NO RS485 NETWORK 12VDC OUT ZONE 2 ZONE 1 RELAY 1 Controller N+ N- NA NB 12VDC IN/OUT RS485 NETWORK ETHERNET SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Add new controller based on an existing controller (see page 17): To duplicate the programming of a previously configured Controller. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Create Floor Plan: Create a floor plan including all inputs and outputs. This is useful for small sites with only a few inputs and outputs. For larger sites it is generally better to create the floor plans manually. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Dynamic IP Address Update: When enabled, the incoming IP address of the controller is detected by the event server, and the IP address field is automatically updated. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 18
(if any) programmed under the associated reader expander will be used. Touchscreen UDP Port: The UDP port that a touchscreen will communicate over. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 19
If the size of the site code and card number are less than 16 bits (e.g. Site Start – Site End is less than 16 bits) use 16 bit, otherwise use 32 bit. If unsure, use 32 bit. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Update All Update button. Allow about 5 seconds per module for the new address to be sent and registered. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 21
Once all modules are online and registered with the desired addresses, the addressing process is complete. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
12VDC OUT ZONE 2 ZONE 1 RELAY 1 When the green and orange wires are connected together, the reader defaults to an entry reader. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
The Controller allows the connection of 2 contacts for monitoring and controlling the door. Typical Configuration of Door Monitoring Contacts: N.C. Input Contact REX Input Door Contact N.O. Input Contact SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Controller. This is not configured by default. Typical Lock Output Connection: 12VDC Electric Locking Device Power Supply SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
REX Input, Port 1 The controller's onboard reader port supports an RS-485 reader interface allowing Genetec 485 readers to be configured. The option is available to select the onboard reader's port type to Genetec 485 from the Reader Expander menu.
When using the No Resistor configuration, the Controller only monitors the opened and closed state of the connected input device generating the alarm and seal conditions. No EOL Resistor Input Configuration: N.C Input Contact SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Open, Closed, Tamper, Short Open, Closed, Tamper, Short Open, Closed, Tamper, Short Open, Closed, Tamper, Short Open, Closed, Tamper, Short Open, Closed, Tamper, Short SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
System restarted Hardware Fault System CP001:30 PoE Connection Lost (PoE model only) Power Fault General CP001:31 Output Over-Current Failure (PoE model Power Fault General only) SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
1K5 OHM Power Supply Warning: The Relay output can switch to a maximum capacity of 7A at 30VAC/DC. Exceeding this amount will damage the output. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Defaulting the Controller does not reset the IP address. Refer to Setting the IP Address (see page 15) for instructions on how to reset the address. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Connect to the web interface by typing 192.168.111.222 into the address bar of your web browser, and view or change the IP address as required. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
The Fault indicator is lit any time the Controller is operating in a non-standard mode. During normal operation the fault indicator is off. State Description Controller is operating normally On (red) Controller is operating in a non-standard mode SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
A LONG flash (>1 second) indicates that the unit has read the data and the format Long flash (red) was correct SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
On (green) Input is in a CLOSED state Flashing (red) Input is in a TAMPER state Flashing (green) Input is in a SHORT state SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Ethernet Interface 12VDC Module Input/Output Battery Backup (PoE models only) RS-485 Module Input Status Indicators PoE Power / Battery Indicators for PoE models only SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
The mechanical layout shown below outlines the essential details needed to help ensure the correct installation of the Controller. 78mm Front Back 60mm 78mm SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
5% of the rated supply voltage. Genetec continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (http://www.genetec.com) for the latest documentation and product information.
New Zealand and Australia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Recognition class 2 (for readers without a keypad) Recognition class 3 (for readers with a keypad) Access class B EN 60839-11-1:2013 Enclosure SY-SIX-DIN-24 has been tested and certified to EN50131. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
Page 40
By design, all Genetec Synergis DIN Rail Enclosures comply with the EN50131 standards. Tamper protection against removal of the cover as well as removal from mounting is provided by tamper switch. Warning: Enclosures supplied by third parties may not be EN50131 compliant and should not be claimed as such.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...
This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAN ICES-3 (A)/NMB-3(A) SY-SIX-CTRL-DIN-1D | Synergis IX DIN Rail Single Door Controller | Installation Manual Last Updated August 2018...