Summary of Contents for Genetec Synergis IX

  • Page 1 Synergis IX Card Reader SY-SIX-TSEC Installation Manual...
  • Page 2 In no event shall Genetec be liable to any person or entity with respect to any loss or damage that is incidental to or consequential upon the instructions found in this document or the computer software and hardware products described herein.
  • Page 3: Table Of Contents

      MIFARE Reading Mode ..........................20   Interface ..............................20   LED Function .............................. 21   Intelligent Tamper ............................22   PIN Data Interface ............................22   SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 4 Technical Specifications ...................... 29   New Zealand and Australia ....................31   European Standards ......................32   FCC Compliance Statements ....................34   Industry Canada Statement ....................35   SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 5: Introduction

    Introduction The Synergis IX Card Reader is an advanced-technology, high-frequency smart card radio frequency identification device (RFID), specifically designed to enhance the functionality of security, building automation and access control by providing multiple format compatibility, high-speed data transmission and sabotage protection.
  • Page 6: Synergis Ix Card Reader Editions

    Synergis IX Card Reader Editions The Synergis IX Card Reader comes in two main sizes and with a range of optional features. Keypad MIFARE/DESFire Standard 115 x 45 x 18mm (4.53 x 1.77 x 0.71") SY-SIX-TSEC-STD-DF-B Standard DESFire Card Reader...
  • Page 7: Mifare Technology

     High security and fraud protection MIFARE/DESfire Products The MIFARE/DESfire products can be expanded to accommodate large numbers of modules using the encrypted RS-485 Network. Genetec provides a number of reader and tag/card options in the MIFARE/DESfire range. Cards ...
  • Page 8: Mounting

    Regular keypad variations of the Reader range do not operate correctly with the vandal resistant covers. You must order the reader (including cover) using the following part code:  SY-SIX-TSEC-STD-DF-KP-VRC SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 9 Other keypad variants will not operate correctly. Mini Size Vandal Resistant Cover 88mm / 3.46” 20mm / 0.78” 6X 5.2mm / 0.2” Mounting Holes 69mm / 2.71” SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 10 Mullion Size Vandal Resistant Cover 22.6mm / 0.88” 91 / 3.58” 8X 5.2mm / 0.2” Mounting Holes 70mm / 2.75” SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 11 Wall Plate Size Vandal Resistant Cover 22.6mm / 0.88” 120mm / 4.72” 8X 5.2mm / 0.2” Mounting Holes 99mm / 3.9” SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 12: Reader Connection

    BLUE YELLOW VIOLET Single LED Connection SHIELD Shielded Cable BLACK GREEN WHITE ORANGE Shield not Shield is frame connected grounded at one point BROWN BLUE YELLOW VIOLET SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 13: Wiegand Reader Connection (Entry / Exit)

    Do not connect the shield to a AUX- or 0V connection.  Do not join the shield and black wires at the reading device.  Do not connect the shield to any shield used for isolated communication. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 14: Rs-485 Reader Locations

    When the green and orange wires are not connected together, the reader defaults to an entry reader. To wire the reader for exit mode, connect the green and orange wires together. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 15: Rs-485 Connection (Entry/Exit)

    330 Ohm EOL resistor must then be inserted between the source NA and NB terminals at the other end of the wiring. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 16: Rs-485 Connection

    Warning: When connecting the Reader in RS-485 Mode you must isolate all unused wiring. DO NOT terminate any unused connections to ground or a voltage or to another connection. Doing so may damage the unit and will void any warranty. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 17: Installer Programming

    The Reader beeps twice to indicate 125kHz programming mode has been entered. Data entry and the menu times out after 2 minutes of no activity and reverts back to normal activity, any programming changes will be lost. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 18: 125Khz Reading Mode

    To change the programmed reading mode, press the A key and the available modes will toggle on the screen.  In 125kHz programming mode, the following options are available by badging a 125kHz programming card once to enter Address 1. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 19: Desfire Reading Mode

    The data sent is the binary reverse order of the CSN. DESfire DESFire is the most secure reading mode. All card access is secured with a different AES 128 bits encryption key. The Genetec DESFire card data is also protected with another AES 256 bit encryption key. Disable No DESFire cards will be read.
  • Page 20: Mifare Reading Mode

    Secured MIFARE cards. Each card has a diversified access key and the data is protected with a unique AES 256 bit encryption key. Genetec Card Setting the reading mode to Genetec Card, allows the reader to read the standard MIFARE Genetec cards. Sector Sector based reading is used to read custom sector and allows the data from the MIFARE sector to be read and then converted to Wiegand data.
  • Page 21: Led Function

    LED and turns on the green LED. Green On The green LED is on by default. Grounding the brown wire turns off the green LED and turns on the blue LED. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 22: Intelligent Tamper

    Expander set with the card format of 26 bit will decode PINs that are 6 digits long as card numbers and handle it as a card. This is the same for HID 34 Bit with 8 digit PINs. Where possible, these combinations should be avoided. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 23: Backlight

    Once you have selected the desired key slot you will be prompted to enter the 6 byte hexadecimal encryption key. This key cannot be read out of the reader and to erase a key program in to a key slot. FFFFFFFFFFFF  SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 24: Custom Format (Mifare Classic Only)

    Description BCD (4 bits, decimal) The Reader loads data as either site or card data as defined by the specifier: Modifier Description Load site Load card Unused SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 25: Factory Reset

    The Clone Card Reading option determines whether non-standard MIFARE compatible cards are read by the reader. To toggle the Clone Card Reading option, press the 2 key. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 26: Clone Card Destroy

    Padded version of the decimal or hexadecimal card serial number. This is padded to 17 characters in decimal and 10 characters in hexadecimal. Two % in a row will place a % in the output SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 27: Save And Restart

    In 125kHz programming mode, badge the programming card 12 times to restart the Reader. The Restart function immediately causes the Reader to exit programming mode and restart. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 28: Technical Diagram

    The dimensions shown below outline the essential details needed to help ensure the correct installation of the Reader. 4.5mm Screw Hole 4.5mm Screw Hole 10mm Cable Hole 10mm Cable Hole 4.5mm Screw Hole 4.5mm Screw Hole 45mm / 1.77” 73mm / 2.87” SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 29: Technical Specifications

    Wall Plate Size: 162 x 120 x 22.6mm (6.37 x 4.72 x 0.88") Mini: 127 x 88 x 0.78mm (5 x 3.46 x 0.78") Weight Mullion Size: 110g (3.89oz) Wall Plate Size: 155.8g (5.5oz) Mini: 80g (2.82oz) SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 30 5% of the rated supply voltage. Genetec continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (http://www.genetec.com) for the latest documentation and product information.
  • Page 31: New Zealand And Australia

    New Zealand and Australia Intentional Transmitter Product Statement The R-NZ compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 32: European Standards

    EN 50131-1:2006+A2:2017, EN 50131-3:2009, EN 50131-6:2008+A1:2014 Recognition class 2 (for readers without a keypad) Recognition class 3 (for readers with a keypad) Access class B EN 60839-11-1:2013 SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 33 SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 34: Fcc Compliance Statements

    NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 35: Industry Canada Statement

    This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAN ICES-3 (A)/NMB-3(A) SY-SIX-TSEC | Synergis IX Card Reader | Installation Manual Last Updated July 2018...
  • Page 36 © Genetec Inc., 2018. Genetec, Synergis, Synergis IX, the Synergis IX logo and the Genetec Logo are trademarks of Genetec Inc., and may be registered or pending registration in several jurisdictions. Other trademarks used in this document may be trademarks of the manufacturers or vendors of the respective products.