Aux Contact

Aux contact function is used for switching on/off other devices automatically or based
on defined schedules
Aux contact settings is only for the end user, whose energy storage system has already
aux contact function. The device should have dry contact function and has been
connected correctly with the system. Or this device can connected correctly with the
system by using a suitable relay.
Currently aux contact function is available on Storion-SMILE-5, later it will be
available on Storion-SMILE-T10.

6.1 Setting on AlphaCloud

Under aux contact function, the UPS mode should be disable.
After wiring the aux contact function can be set on the server.
1. Click "System setup" and click "AUX Contact setting", then the following inter-face
appears:
2. Click AUX Contact Channel to choose AUX 1 or AUX 2. Two devices can be
controlled.
3. Click "enable" to set if the function for the chosen channel is available.
4. Click "Control Mode" to set the function mode, we have 3 modes for the AUX contact:
On, Off and Auto.
a. Control Mode On
___________________________________________________________________
Alpha ESS Co., Ltd.
Page 11 of 16