Download Print this page

TCW Technologies Integrated Back-up Battery System Manual page 18

Advertisement

15 pin, female
Dsub connector
1
15
14
13
12
2
8
7
6
5
11
10
9
20 awg
Main Aircraft Bus
5 amp
10 amp
5 amp
Master Solenoid
Battery
NOTES:
1) Use redundant ground pins 9,10,11
2) Use redundant power inputs 6,7,8 based on load current of connected equipment.
3) No back-up master switch required when wired per this drawing for AFS 5000 series.
4) Enable Volts2 display in AFS setup screen to display IBBS battery voltage
REV 1.6
Wiring Diagram IBBS-12v-6ah
Wiring Advanced Flight Systems 5000 series
INTEGRATED
Back-up Battery
SYSTEM
MODEL: IBBS-12V-6AH
Input: 10-15 volts DC
Output: 12 volts,8 amps
22 awg
output
output
20 awg
20 awg
main power input on
main connector
www.tcwtech.com
Emmaus, PA USA
Output, to additional AFS efis
Expansion connector
Back-up pwr input pin 6
Volts2 input pin 13
pin6
pin13
Advanced Flight
pin1
pin 15
© 2019 TCW Technologies, LLC.
18
Systems
5000 series

Advertisement

loading

This manual is also suitable for:

Ibbs-12v-ah