SPECIFICATIONS:
Input Voltage:*
Transition Voltage: ** 10.5-11.5 volts
Input Current:
Pass-thru Current:
Output Voltage:
Output Current:
Battery:
Charger:
Surge Protection:
Wiring:
Enclosure:
Weight:
Temperature range:
Connector:
Standard density 15 pin male D-sub on product
*Minimum input voltage for battery recharging.
**Transition voltage is the voltage level on the input that causes the system to provide output power via the internal
back-up battery
REV 1.6
13-15 volts DC
4.0 amps max continuous on main input for charging
8 amps continuous, 12 amps peak (30 seconds)
10-14 volts DC during back-up operation
8 amps continuous
12 amps peak for radio transmissions and transient
load (30 second duration max)
Internal sealed Li-Fe-PO4
Integral high performance fast charger
34 volt active clamp, 1500w 10/1000uS waveform
15 pin male D-sub on product.
Aluminum 7.7" x 2.3" x 2.65"
34 oz.
Operating -10 C° to 60 C°
Charging
0 C° to 40 C°