REV L. P/N: 1072-05 EN
English Manual
www.tikisafety.com
Pat.No. D755953

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D755953 and is the answer not in the manual?

Questions and answers

Summary of Contents for tiki D755953

  • Page 1 REV L. P/N: 1072-05 EN English Manual www.tikisafety.com Pat.No. D755953...
  • Page 3 30° 30°...
  • Page 4: Table Of Contents

    The seal must be tested before be used in. The Tiki does not supply oxygen and must not every use. be used in atmospheres having less than 19.5% oxygen Do not use the Tiki respirator in an emergency/rescue content.
  • Page 5: Components

    2. Components The Tiki is a powered air purifying respirator (PAPR) that uses filters to remove harmful airborne contaminants. It is made up of several components. The basic components required for the unit to function are the mask, blower, filter and harness. The external battery pack extends the battery life of the mask and the charger is required to charge both the blower unit and the external battery.
  • Page 6: Seal Check And Fit Testing

    Reset function Each time you start using your Tiki respirator you should reset the blower unit. This action is to ensure the software is reset and good to go. (Fig 11, page 3). Reset the blower unit by holding it upside-down (with the buttons facing up). Start by pressing the light-button first (Fig 11c, page 3), then press down the on/off-button (Fig 11a, page 3).
  • Page 7: Warning System Check

    Step 5. Switch the unit on by holding down the power button for 3 seconds. (Fig 11a, page 3) The blower unit should temporarily increase in speed until the unit can establish that the pressure inside the mask is positive. After a few seconds the fan inside the blower unit will slow down as it optimises the airflow to the required amount.
  • Page 8: Changing Mask And Filter

    8. Cleaning and Care The Tiki has been designed to be used for a long time. If the mask is contaminated it can be cleaned and disinfected and put to use again. If it is damaged it should be recycled. If it is contaminated beyond restoration it should be disposed of.
  • Page 9: Recycling

    Approval: EN 12942 TM3P R SL, CE 0158 minimum of 60 minutes. WARNING Do not use the Tiki respirator in explosive environments. Use only accessories manufactured by Tiki Safety AB. Batteries: The blower unit and the external battery pack both contain In the unlikely event that the batteries are damaged and electrolyte seeps out, keep away from eyes.
  • Page 10 Part number: Tiki Starter Pack, small 1050-51 Tiki Starter Pack, medium 1050-52 Tiki Starter Pack, large 1050-53 Tiki Mask 5 Pack, small 1010-51 Tiki Mask 5 Pack, medium 1010-52 Tiki Mask 5 Pack, large 1010-53 P3 Particle Filter, 2 pcs...
  • Page 11: Product Warranty

    Any times/measure ments in this manual are taken under optimal conditions. Charging times and Tiki Safety AB will replace at no charge for parts only or, at its operational times may vary depending on temperature, filter option, replace any product or part of the product that proves type, amount of particles in the air, heavy breathing etc.
  • Page 12 M AD E IN SWED EN Developed and patented by: Tiki Safety AB Tiki Breathing Face Protection www.tikisafety.com Pat.No. D755953 Printed in Sweden. All rights reserved Tiki Safety AB ©2019.