Smiths Medical Graseby 500 Technical  User's Manual

Smiths Medical Graseby 500 Technical User's Manual

Volumetric infusion pump

Advertisement

Quick Links

Smiths Medical Publications
This publication has been compiled and approved by Smiths
Medical for use with their respective products. It is supplied in
this format to permit users to access the text and illustrations
for their own use e.g. training and educational purposes.
Users of the equipment must ensure that they have read and
understood the contents of the complete manual including the
warnings and cautions and have been trained in the correct use
of the product.
Smiths Medical cannot be held responsible for the accuracy and
any resulting incident arising from information that has been
extracted from this publication and compiled into the users
documentation.
This publication maybe subject to revision and it is the users
responsibility to ensure that the correct version of manual/
text/illustration is used in conjunction with the equipment.

Advertisement

Table of Contents
loading

Summary of Contents for Smiths Medical Graseby 500

  • Page 1 Smiths Medical cannot be held responsible for the accuracy and any resulting incident arising from information that has been extracted from this publication and compiled into the users documentation.
  • Page 2 ® Graseby Model 500 ® and Graseby Micro 505 Volumetric Infusion Pump Technical User Manual...
  • Page 3 Company number 362847 Trademarks and acknowledgements: Graseby is a trademark of the Smiths Medical family of companies. The symbol ® indicates that it is registered in the U.S. Patent and Trademark office and certain other countries. The products described are covered by one or more of the following Patent Nos.: U.S.
  • Page 4 The pump must be referred to a suitably qualified WARNING: When delivering drugs in the technician or returned to Smiths Medical in epidural space, use only those medications order to have the fault rectified. specifically indicated for epidural use.
  • Page 5 20. WARNING: Check the Secondary set carefully, 28. WARNING: While Smiths Medical have taken since an occlusion above the pump on the all reasonable steps to ensure that the pump Secondary line could cause the Primary fluid...
  • Page 6 W a r n i n g s a n d C a u t i o n s S m i t h s M e d i c a l Cautions Cautions tell you about dangerous conditions that can occur and cause damage to the pump if you do not obey all of the instructions in this manual.
  • Page 7 S m i t h s M e d i c a l W a r n i n g s a n d C a u t i o n s V o l u m e t r i c I n f u s i o n P u m p s...
  • Page 8: Table Of Contents

    S m i t h s M e d i c a l C o n t e n t s C o n t e n t s Who should read this manual ................. 1 Introduction ....................... 1 Contents of the box ................... 2 Checking labels and serial number ..............
  • Page 9 C o n t e n t s S m i t h s M e d i c a l V o l u m e t r i c T e c h n i c a l U s e r G u i d e...
  • Page 10: Who Should Read This Manual

    Manual, available on request from information are not needed by most Smiths Medical. users, so they are separated into this stand-alone manual. W h o s h o u l d r e a d t h i s m a n u a l You should be familiar with the use of •...
  • Page 11: Contents Of The Box

    The pump should not be used if damage is evident. Contact your Smiths Medical Service Department V o l u m e t r i c I n f u s i o n P u m p...
  • Page 12: Checking Labels And Serial Number

    Epidural Label Set for the Volumetric replacement parts. Infusion Pump (part number TPF-00306) is available from Smiths Medical. V o l u m e t r i c I n f u s i o n P u m p...
  • Page 13: Functional Inspections And Tests

    T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l F u n c t i o n a l i n s p e c t i o n s a n d t e s t s Perform the following tasks when you Power up and self test have taken the pump out of the...
  • Page 14 If any of the following faults occur prime a ‘Standard Adult Set, 8C-820’ with a new pump, contact your (non-checkvalve 20 drop/mL) Smiths Medical Service Department. administration set Product Code • if any LEDs do not light in steps 1, 3 21-0346-25 for the following tests.
  • Page 15 If you have a new pump and it does 6. Press the Run key and then press not behave as described here, the Options key. Verify that the contact your Smiths Medical message display shows the time Service Department. remaining with a value like the...
  • Page 16 If you have a new pump and it does and push it into its slot. Close the not behave as described here, clamp above the cassette. Then close contact your Smiths Medical the door and silence the alarm when Service Department. this message appears:...
  • Page 17: Setting Up

    T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l S e t t i n g u p Battery charging Enabling limits Before using the pump for clinical use,...
  • Page 18: Regular Testing

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l R e g u l a r t e s t i n g In addition to the regular testing requirements listed below, Smiths Medical recommends that a qualified...
  • Page 19: Menus

    T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l M e n u s There are several menus on the pump, The Biomedical menu some of which have an overlap of This menu is the one that also exists in...
  • Page 20: Technician Menu

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l Te c h n i c i a n m e n u This menu allows you to define how the You cannot move back through the pump behaves by setting values or by...
  • Page 21: Technician Parameters

    T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l Technician parameters The numbers on the left of this table show the number of Options key presses to reach the parameter.
  • Page 22: Using Technician Parameters

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l Using Technician parameters Most parameters enable or disable can be infused for a Primary infusion.
  • Page 23 T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l Enabling this feature allows users to Secondary stop use the Options key to put the pump With this parameter enabled, the pump into a mode in which they can change...
  • Page 24 S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l When the pump is in use, if the date set Backlight is reached or exceeded, then the This parameter sets the default for how...
  • Page 25: Biomedical Menu

    T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l are displayed for security protection. If B i o m e d i c a l m e n u you make a mistake, you must switch the pump off to enter the correct ID.
  • Page 26: Biomedical Menu Parameters

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l B i o m e d i c a l m e n u p a r a m e t e r s The numbers in the left hand column of this table indicate the number of Options key presses to reach the parameter.
  • Page 27 T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l Screen Notes Shows the current rate Rates of 300, 600, setting of the serial port.
  • Page 28: Service Functions Menu

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l S e r v i c e F u n c t i o n s m e n u The Service Functions menu allows you Using the Service Functions menu to set the date and time on the pump...
  • Page 29: Service Functions Menu Parameters

    S e r v i c e F u n c t i o n s m e n u p a r a m e t e r s Screen Notes Information for Smiths Medical Service Department use. Use this to set the time 1.
  • Page 30: Sensors Screen

    S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l Sensors screen Value = 0 Value = 1 Door Closed Open...
  • Page 31 T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l V o l u m e t r i c I n f u s i o n P u m p...
  • Page 32: Specifications

    S p e c i f i c a t i o n S m i t h s M e d i c a l S p e c i f i c a t i o n s General Weight 5 kg (11 pounds).
  • Page 33 Test solution Sterile water or normal saline at room temperature (70°F ±5°/21°C ±3°). Smiths Medical standard (primary), 20 drops/mL, non-checkvalve administration set (8C820). Testing conditions Model 500 Fluid level in the solution container 46 cm (18 inches) above top of the pump, rate set at 999 mL/h and volume to be infused of 49 mL.
  • Page 34 S p e c i f i c a t i o n S m i t h s M e d i c a l Power AC power supply Internally configured for either 100-120 V AC, 200 mA, 50/60 Hz. 220-240 V AC, 80 mA, 50/60 Hz.
  • Page 35 S p e c i f i c a t i o n S m i t h s M e d i c a l Primary and Secondary Infusions: Rate range Model 500 Range Increment 0.1 to 99.9 mL/h 0.1 mL/h 1 to 999 mL/h 1 mL/h...
  • Page 36 S p e c i f i c a t i o n S m i t h s M e d i c a l Volume Over Time Infusions: Rate range Model 500 Range Increment 0.1 to 99.9 mL/h 0.1 mL/h 1 to 999 mL/h 1 mL/h...
  • Page 37 S p e c i f i c a t i o n S m i t h s M e d i c a l Drug amount modes/range Mode Range Increment MG drug/bag 0.01 to 99.99 0.01 0.1 to 999.9 1 to 99999 Gm drug/bag 0.01 to 99.99...
  • Page 38 0.1 to 3.0 mL/h Accessories For a complete list of Administration Sets, please contact Smiths Medical or your local distributor. V o l u m e t r i c I n f u s i o n P u m p...
  • Page 39 S p e c i f i c a t i o n S m i t h s M e d i c a l Symbols used on the pump Front panel symbols Inside battery door symbols Battery is charging/mains Attention: dangerous power applied.
  • Page 40: Standards

    European Council Directive 93/42/EEC concerning medical devices. 0473 The number 0473 identifies the Notified Body under which the Quality Systems operated within Smiths Medical are assessed. Disposal When the time comes to dispose of the pump, its batteries, or any of its accessories, do so in the best way to minimise any negative impact on the environment.
  • Page 41: Trumpet Curves

    S p e c i f i c a t i o n S m i t h s M e d i c a l Tr u m p e t c u r v e s The curves were developed while The trumpet curve represents the worst testing the Model 500 using a Smiths case rate error in any given observation...
  • Page 42 S p e c i f i c a t i o n S m i t h s M e d i c a l V o l u m e t r i c I n f u s i o n P u m p S —...
  • Page 43 S p e c i f i c a t i o n S m i t h s M e d i c a l S — 1 2 V o l u m e t r i c I n f u s i o n P u m p...
  • Page 44 S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l - I n d e x I n d e x AC cord retainer 4 Damaged pump 2 Acceptance test 4...
  • Page 45 I n d e x - T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l Occlusion Alarm default rate S - 7 approx values of settings S - 7 rate entry parameter 13...
  • Page 46 S m i t h s M e d i c a l T e c h n i c a l U s e r M a n u a l - I n d e x Service Functions menu description 19 Unpacking pump 2 overview 10...
  • Page 47: Index

    I n d e x - T e c h n i c a l U s e r M a n u a l S m i t h s M e d i c a l I n d e x — 4 V o l u m e t r i c I n f u s i o n P u m p...
  • Page 48 Smiths Medical International Limited Smiths Medical International Limited Watford, Hertfordshire, UK, WD24 4LG www.smiths-medical.com Made in Malaysia Part No. 0166-0202-D Jan 2005 Smiths Medical - A part of Smiths Group plc © 2005 Smiths Medical family of companies. All rights reserved...