 Warning
 Safety Information
Understand and follow operating instructions carefully.
Use the meter only as specified in this manual; otherwise,
the protection provided by the meter may be impaired.
 WARNING
Identifies hazardous conditions and actions that could cause
BODILY HARM or DEATH
 CAUTION
Identifies conditions and actions that could DAMAGE the meter
or equipment under test
 WARNING
˙ When using test leads or probes, keep your fingers behind
the finger guards.
˙ Remove test lead from Meter before opening the battery
door or Meter case.
˙ Use the Meter only as specified in this manual or the protec-
tion by the Meter might be impaired.
˙ Always use proper terminals, switch position, and range for
measurements.
˙ Verify the Meter's operation by measuring a known voltage.
If in doubt, have the Meter serviced.
˙ Do not apply more than the rated voltage, as marked on
Meter, between terminals or between any terminal and
earth ground.
˙ Only replace the blown fuse with the proper rating as
specified in this manual.
˙ Use caution with voltages above 30 Vac rms, 42 Vac peak,
or 60 Vdc. These voltages pose a shock hazard.
˙ To avoid false readings that can lead to electric shock and
injury, replace battery as soon as low battery indicator.
˙ Disconnect circuit power and discharge all high-voltage
capacitors before testing resistance, continuity, diodes, or
capacitance.
˙ Do not use Meter around explosive gas or vapor.
˙ To reduce the risk of fire or electric shock do not expose this
product to rain or moisture.
˙ Wear suitable personal protective equipment when working
around or near hazardous live conductors which could be
accessible.
Safety sheet
Warning
Safety sheet
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . . .
 Read First
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDM 98IV and is the answer not in the manual?

Questions and answers

Summary of Contents for RS PRO IDM 98IV

  • Page 1 IDM 98IV & 99IV / EN  Warning Safety sheet  Warning Safety sheet ......
  • Page 2: Unsafe Voltage

    IDM 98IV & 99IV / EN  CAUTION ˙ Disconnect the test leads from the test points before chang- ing the position of the function rotary switch. ˙ Do not expose Meter to extremes in temperature or high humidity. ˙ Never set the meter in Ω,...
  • Page 3 IDM 98IV & 99IV / EN Introduction The Meter Description Front Panel Illustration 1. LCD display : 6000 counts 2. Push-buttons. 3. Rotary switch for turn the Power On / Off and select the function. 4. Input Terminal for A.
  • Page 4: Unpacking And Inspection

    IDM 98IV & 99IV / EN Feature • 6000 count digital display. • 62 segment bar graph . • Extra Large scale display and white backlit • True RMS • 0.08% basic DCV accuracy • Automatic AC/DC Voltage detect with low impedance (Auto-V LoZ) •...
  • Page 5: Making Basic Measurements

    IDM 98IV & 99IV / EN Making Basic Measurements Preparation and Caution Before Measurement  : Observe the rules of  Warnings and  Cautions The figures on the following pages show how to make basic measurements.  Caution When connecting the test leads to the DUT (Device Under Test) connect the common test leads before connecting the live test leads ;...
  • Page 6 IDM 98IV & 99IV / EN Measuring AC/DC Current Frequency Disconnect Rotate the switch and press the Function button to select the measuring function. See “Using the Function Button” Measuring AC/DC Current Disconnect Rotate the switch and press the Function button to select the measuring function.
  • Page 7 IDM 98IV & 99IV / EN Measuring Resistance/Capacitance Resistance Capacitance Resistance Capacitance Rotate the switch and press the Function button to select the measuring function. See “Using the Function Button” Measuring Continuity / Diode Rotate the switch and press the Function button to select the measuring function.
  • Page 8 IDM 98IV & 99IV / EN Measuring Temperature °C / °F (for 99IV only) Rotate the switch and press the Function button to select the measuring function. (°C / °F) See “Using the Function Button”...
  • Page 9: Using The Function Buttons

    IDM 98IV & 99IV / EN Using The Function Buttons Function Button Press Switch Function Position Press the Function button to change the function on the same switch position. RANGE Button Press button > 2sec to Auto Range Mode.
  • Page 10 IDM 98IV & 99IV / EN MIN/MAX Present Reading Max. Reading Press button over 2 sec. to exit this function Min. Reading The MAX/MIN mode records the min. and max. input values. When the input goes below the recorded min. value or above the recorded max.
  • Page 11 IDM 98IV & 99IV / EN Smart HOLD The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts. (However ,it can not detect across the AC and DC Voltage / Current).
  • Page 12 IDM 98IV & 99IV / EN Backlight Press the Backlight button to turn the backlight on/off. Auto Power Off After idle 20 min. Reactivate the meter by rotating the switch or by pressing any button. Auto Power Off Disable Rotate the switch to the “OFF” position, Press and hold down...
  • Page 13 IDM 98IV & 99IV / EN Testing the LCD Display Rotate the switch to the “OFF” position, Press and hold down the "SmartHOLD" button and turn the meter on. Default Temperature Units (for only) 99IV Rotate the switch to the “OFF” position, Press and hold down...
  • Page 14: Battery And Fuse Replacement

    IDM 98IV & 99IV / EN Battery and Fuse Replacement  Caution The following safety information must be observed to ensure maximum personal safety during the operation of this instru- ment. 1. To avoid electric shock, disconnect the test leads before replacing the instrument fuses or batteries.
  • Page 15 IDM 98IV & 99IV / EN Low Battery and Battery Replacement Replace the battery as soon as the low battery indicator appears, to avoid false reading. Refer to the following figure to replace the batteries. Screw Battery Cover 9V Battery ...
  • Page 16: General Specifications

    IDM 98IV & 99IV / EN Specifications General Specifications Maximum voltage applied to any terminal : 1000 V rms or 1000 V . rms Display : 6000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL...
  • Page 17: Electrical Specifications

    IDM 98IV & 99IV / EN Weight : 460g (including battery) Dimensions (W x H x D) : 94mm x190mm x 48mm with holster. Accessories : Battery (installed), Test leads and user manual. (The probe assembly provided with the product are for use with...
  • Page 18 IDM 98IV & 99IV / EN AC 600.0mV ranges are specified from 1 % of range to 100 % of range. Input Impedance: 10MΩ // less than 100pF Overload Protection: AC/DC 1000V (3) DC Voltage For 98IV For 99IV Range...
  • Page 19 IDM 98IV & 99IV / EN (6) A Current For 98IV For 99IV Range Resolution Accuracy Accuracy 0.001A ± (1.0% + 3d) ± (0.8% + 3d) 6.000A 0.01A ± (1.0% + 3d) ± (0.8% + 3d) 10.00A 6.000A 0.001A ± (1.5% + 3d) ±...
  • Page 20 IDM 98IV & 99IV / EN (10) Diode Test Range Resolution Accuracy ± (1.5% + 2d) 1.500V Open Circuit Voltage : Approx. 1.8V Overload Protection : AC/DC 1000V. (11) Capacitance Range Resolution Accuracy 1.000μF 0.001μF ± (1.2% + 5d) 10.00μF 0.01μF...
  • Page 21 IDM 98IV & 99IV / EN "Note : (14)(15)(16)(17) The AC+DC True RMS value might be over the selected range because the AC signal may contain a DC level." (14) AC+DC Voltage For 98IV For 99IV Range Resolution Accuracy Accuracy 6.000V...
  • Page 22: Limited Warranty

    IDM 98IV & 99IV / EN Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.
  • Page 23 Africa RS Components SA P.O. Box 12182, Vorna Valley, 1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa www.rs-components.com Asia RS Components Pte Ltd. 31 Tech Park Crescent Singapore 638040 www.rs-components.com China RS Components Ltd. Suite 23 A-C East Sea Business Centre Phase 2 No.
  • Page 24: Digital Multimeter

    Instruction Manual IDM 98IV & IDM 99IV Digital Multimeter ...

This manual is also suitable for:

Idm 99iv873-2367873-2708

Table of Contents