Download Print this page

Graco 24Z714 Instructions Manual

Proximity switch cable

Advertisement

Quick Links

Instructions
Proximity Switch Cable
Flying lead cable with LED and adapter cables for use with 10-32 VDC, single control, PNP,
proximity switch.
Not approved for use in European explosive atmosphere locations.
Part Nos.:
24Z714 - Cable, M12 to 5 Pin, NPN Adapter*
24Z715 - Cable, M12 to 3 Pin, NPN Adapter*
24Z716 - Cable, M12 to 4 Pin, NPN Adapter*
24Z719 - Cable, M12 to 4 Pin, PNP
24Z720 - Cable, M12 with PNP LED to Flying Leads, PNP, 90°, 5m
26A782 - Cable, M12 with PNP LED to flying Leads, PNP, 90°, 10m
25M604 - Cable, M12 with PNP LED to Flying Leads, PNP, Straight
25M602 - Cable, M12 with NPN LED to Flying Leads, PNP, Straight**
25M603 - Cable, M12 with NPN LED to M12, PNP Straight**
*NPN adapter cable connects to the PNP switch and inverts the signal to NPN for the controller.
**When LED indication is desired on a G3 Max, G3 SP, or G3 DMS pump, an NPN LED configuration is needed. The
sensor output is still a PNP switch.
Important Safety Instructions
Read all warnings and instructions in this
manual and the instructions included with
your operating system or pump. Save
these instructions.
Related Manual
Manual No.
3A4144
Manual Title
Proximity Switch
3A4481F
EN

Advertisement

loading

Summary of Contents for Graco 24Z714

  • Page 1 Not approved for use in European explosive atmosphere locations. Part Nos.: 24Z714 - Cable, M12 to 5 Pin, NPN Adapter* 24Z715 - Cable, M12 to 3 Pin, NPN Adapter* 24Z716 - Cable, M12 to 4 Pin, NPN Adapter* 24Z719 - Cable, M12 to 4 Pin, PNP 24Z720 - Cable, M12 with PNP LED to Flying Leads, PNP, 90°, 5m...
  • Page 2: Installation

    Installation Installation Models 24Z720, 26A782, 25M602, 25M603, 25M604 NOTE: Before installing the proximity switch cable, install the proximity switch. See the Proximity Switch instruction manual (provided with the proximity switch) for these instructions. Instructions Disconnect power. Connect flying leads. Refer to F .
  • Page 3 Installation Model - 25M602: NPN LED, Straight M12 Model - 25M603: NPN LED Model - 25M604: PNP LED, Straight, M12 3A4481F...
  • Page 4 Installation Models 24Z714-24Z716 and Instructions 24Z719 Disconnect power. Steps 2 - 4 only apply to cable kits 24Z714, 24Z715 and NOTE: 24Z716. • Before installing the proximity switch cable, install the Disconnect the green wire with a yellow stripe that is proximity switch.
  • Page 5 Installation Model - 24Z719 Cable Connector 1 Connector 2 Polarity Length Straight 4 Pin 12 in. Connector - 24Z715 Cable Connector 1 Connector 2 Polarity Length Straight 3 Pin 12 in. 3A4481F...
  • Page 6: Graco Information

    12 in. Graco Information TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590 All written and visual data contained in this document reflects the latest product information available at the time of publication.