Contents Contents General information........................ 5 About this documentation .................... 5 Other applicable documentation .................. 5 Structure of the safety notes ................... 5 Decimal separator in numerical values ................ 6 Rights to claim under limited warranty ................ 6 Product names and trademarks.................. 7 Copyright notice ...................... 7 Safety notes .......................... 8 Preliminary information .................... 8 Duties of the user...................... 8 Target group ........................ 8...
Page 4
Contents Technical data and dimension sheets .................. 34 Technical data....................... 34 Pin assignment ...................... 40 Cable.......................... 42 Dimension sheets ...................... 46 Appendix .......................... 54 Chemical resistance...................... 54 Address list .......................... 57 Index ............................ 68 Operating Instructions – DOP11C Operator Panels...
General information About this documentation General information About this documentation The current version of the documentation is the original. This documentation is an integral part of the product. The documentation is intended for all employees who perform work on the product. Make sure this documentation is accessible and legible.
General information Decimal separator in numerical values 1.3.2 Structure of section-related safety notes Section-related safety notes do not apply to a specific action but to several actions pertaining to one subject. The hazard symbols used either indicate a general hazard or a specific hazard.
Safety notes Preliminary information Safety notes Preliminary information The following general safety notes serve the purpose of preventing injury to persons and damage to property. They primarily apply to the use of products described in this documentation. If you use additional components, also observe the relevant warning and safety notes.
Safety notes Designated use Specialist for elec- Any electrotechnical work may be performed only by electrically skilled persons with a trotechnical work suitable education. Electrically skilled persons in the context of this documentation are persons who are familiar with electrical installation, startup, troubleshooting, and main- tenance of the product who possess the following qualifications: •...
Safety notes Network security and access protection Network security and access protection A bus system makes it possible to adapt electronic drive technology components to the particulars of the machinery within wide limits. There is a risk that a change of pa- rameters that cannot be detected externally may result in unexpected but not uncon- trolled system behavior and may have a negative impact on operational safety, system availability, or data security.
Safety notes Electrical connection 2.10 Electrical connection Familiarize yourself with the applicable national accident prevention regulations before working on the product. Perform electrical installation according to the pertinent regulations (e.g. cable cross- sections, fusing, protective conductor connection). The documentation at hand con- tains additional information.
Device structure Type designation and nameplates Device structure Type designation and nameplates 3.1.1 Sample type designation Example: DOP11C-51 Type DOP = Drive Operator Panel Generation Size TFT-/LCD display with 5-inch screen diagonal Design 1 = Plastic 2 = Aluminum The following sizes and designs of the operator panel are available: •...
Device structure Scope of delivery 3.1.2 Example nameplate The nameplate is attached to the rear of the device. 29812261515 Scope of delivery Included in the delivery: • DOP11C operator panel • Installation material • Connector for DC 24 V, 5 mm, 3-pin •...
Device structure Connections of the operator panel Connections of the operator panel 3.3.1 Connections on the underside Below, you can find a description of the connections on the underside of the different designs of the operator panel. For detailed information, refer to chapter "Technical data and dimension sheets" (→ 2 34).
Page 15
Device structure Connections of the operator panel Connections of DOP11C-102, -122, 152 19270735755 Item Connection Description Voltage supply DC 24 V (DC 18 – 32 V) 1 x USB host 2.0, maximum output current USB interface 500 mA Ethernet interface 1 x 10/100 Base-T (shielded RJ45) (LAN A) Ethernet interface 1 x 10/100 Base-T (shielded RJ45) (LAN B) Communication ports (serial, 9-pin D-sub)
Page 16
Device structure Connections of the operator panel Item Connection Description 1 x USB host 2.0 with a maximum output current of USB interface 500 mA SD memory card slot 1 x SD memory card (optional) INFORMATION The following operator panels do not have a SD memory card slot: •...
Installation Installation notes for the basic unit Installation WARNING Electric shock due to incorrect installation. Severe or fatal injuries. • Observe the safety notes in the chapter "Installation" (→ 2 10). INFORMATION Place the device on a stable surface during installation. If the device falls down, it could be damaged.
Installation UL-compliant installation 9007200661451659 • You can also use grounded sheet-metal ducts or metal pipes to shield the cables. Route the power and signal cables separately. • Ground the device using the built-in connector for a voltage supply of 24 V. UL-compliant installation INFORMATION Due to UL requirements, the following chapter is always printed in English indepen-...
Page 19
Installation UL-compliant installation Flat surface For use on a flat surface of a type 4X enclosure indoor use only. Power terminals Use minimum 75 °C copper wire only. Wiring connections To make wiring connections to the power supply connector, follow the table with cable and torque specifications below: Terminal Block Con- Wire Size AWG...
Installation Space required for installation Space required for installation The following figure shows the required space for installing the operator panel: 9007208050429835 Thickness of mounting plate The thickness of the mounting plate depends on the device design. 4.4.1 Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101...
Installation Unpacking the operator panel Unpacking the operator panel Proceed as follows: 1. Unpack the delivery and check it. 2. Inform your supplier immediately in the event of damage. Mounting the operator panel How the operator panel is mounted depends on the used device design. 4.6.1 Mounting the DOP11C-51, -71, -101 Proceed as follows:...
Page 22
Installation Mounting the operator panel 4.6.2 Mounting the DOP11C-42, -72, -102 Proceed as follows: 1. Use all the retaining slots and the brackets and screws supplied to mount the oper- ator panel: 19312007051 2. Tighten the screws with a tightening torque of 0.5 – 1.0 Nm. Operating Instructions –...
Installation Connecting the operator panel 4.6.3 Mounting the DOP11C-122, -152 Proceed as follows: 1. Loosen the screw [1] with a screwdriver (Torx, TX7) [2] until the retaining clamp [3] tilts up. 9007208208698763 Screw (Torx, M4) Screwdriver (Torx, TX7) Retaining clamp 2.
Page 24
Installation Connecting the operator panel The following figure shows the installation diagram of the operator panel: 9007208087637387 Control cabinet door/front panel Operator panel Control cabinet Controller Power supply unit (voltage supply) Ethernet Connect the cables in the order indicated. Proceed as follows: 1.
Installation Connecting the operator panel to the inverter and engineering PC Connecting the operator panel to the inverter and engineering PC WARNING Risk of crushing if the motor starts up unintentionally via the connected ® MOVIDRIVE inverter. Severe or fatal injuries. •...
Page 26
Installation Connecting the operator panel to the inverter and engineering PC 1. Connect the operator panel and the inverters. For detailed information, refer to chapter "RS485 connection" (→ 2 26). EURODRIVE DFE24B DFE24B EtherCAT EtherCAT EURODRIVE EURODRIVE RS485 EURODRIVE DFE24B DFE24B EtherCAT EtherCAT EURODRIVE EURODRIVE RS485...
Page 27
Installation Connecting the operator panel to the inverter and engineering PC ® The operator panel can be directly connected to a MOVIDRIVE inverter via the RS485 COM interface using a 9-pin D-sub connector. Wiring diagram RS485 interface The following figure shows the RS485 connection of the operator panel to the invert- ers: EURODRIVE DFE24B...
Page 28
Line resistance 100 – 150 Ω at 1 MHz • Capacitance per unit length ≤ 40 pF/m (12 pF/ft) at 1 Hz For example, the following cables are suitable: • Prefabricated cables from SEW-EURODRIVE. For further information, refer to chapter "Prefabricated communication cables" (→ 2 42). ® • UNITRONIC BUS CAN, 2 x 2 x 0.22 mm by Lappkabel.
Page 29
Installation Connecting the operator panel to the inverter and engineering PC Cable length The permitted total cable length is 200 m. Potential shift NOTICE Malfunction of devices connected with RS485 due to potential shift. Possible damage to property. • Take suitable measures to avoid potential shift, e.g. by connecting the unit grounds (GND) using a separate cable.
Installation Connecting a voltage supply Connecting a voltage supply NOTICE Damage to the device due to reversed polarity during connection. Possible damage to property. • Ensure correct polarity when making the connection. The following figure shows the connection of the voltage supply: 9007208307719819 Grounding 0 V...
Startup Starting the operator panel Startup For a successful startup, a correct electrical connection of the operator panel is re- quired. WARNING Risk of injury if the operator panels perform any safety functions without higher-level safety systems. Severe or fatal injuries. •...
Operation Opening the service menu Operation Opening the service menu INFORMATION The following procedure describes how to open the service menu if a project was already uploaded to the operator panel. Proceed as follows: 1. Close the operator panel and switch on the voltage supply. ð...
Page 33
Service Waste disposal Service Waste disposal Dispose of the product and all parts separately in accordance with their material struc- ture and the national regulations. Put the product through a recycling process or con- tact a specialist waste disposal company. If possible, divide the product into the follow- ing categories: •...
Technical data and dimension sheets Technical data Technical data and dimension sheets Technical data 8.1.1 Part numbers Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101 Part number 17977541 19500726 19500734 Operator panels in design ..2 DOP11C-42 DOP11C-72 DOP11C-102 DOP11C-122 DOP11C-152 Part number 19500742 19500750...
Page 35
Technical data and dimension sheets Technical data 8.1.3 Touchscreen Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101 Resolution (pixel) 800 x 480 800 x 480 800 x 480 (16:9) (16:9) (16:9) Active screen size, 108 × 64.8 mm 154.1 × 85.9 mm 222 x 132.5 mm W x H (5") (7") (10.1") Brightness (cd/m Contrast 500 : 1 500 : 1 400 : 1 Background lighting Service life of the back-...
Page 36
Technical data and dimension sheets Technical data Operator panels in design ..2 DOP11C-42 DOP11C-72 DOP11C-102 DOP11C-122 DOP11C-152 Resolution (pixel) 480 x 272 800 x 480 1024 x 600 1280 x 800 1280 x 800 (16:9) (16:9) (16:9) (16:10) (16:10) Active screen size, 95.0 × 53.9 mm 152.4 x 91.4 mm 222.7 x 125.3 mm 261.1 x 163.2 mm 331.2 x 207 mm W x H (4.3") (7") (10.1") (12.1") (15.4")
Page 37
Technical data and dimension sheets Technical data 8.1.4 Housing Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101 Front dimensions 170.4 x 106.8 x 7.5 mm 196 x 146 x 7.5 mm 284.3 x 186.6 x 7.5 mm W × H × D Cutout 160.4 x 93 mm 185.8 x 135.8 mm 274.3 x 176.6 mm W × H Installation depth/In- stallation depth incl. 41.7 mm/141.7 mm 44.7 mm/145 mm 44.7 mm/145 mm clearance...
Page 38
Technical data and dimension sheets Technical data 8.1.5 Ambient Conditions Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101 Operating temperature -10 °C – +50 °C Storage temperature -20 °C – +60 °C Rel. Air humidity 5% – 85% (non-condensing) Operator panels in design ..2 DOP11C-42 DOP11C-72 DOP11C-102 DOP11C-122 DOP11C-152 Operating temperature -10 °C – +60 °C Storage temperature -20 °C – +70 °C...
Page 39
Technical data and dimension sheets Technical data 8.1.7 Communication and memory Operator panels in design ..1 DOP11C-51 DOP11C-71 DOP11C-101 COM1 RS232 and COM2 RS422/RS485 9-pin D-sub connection, installed connector with 4-40 UNC retaining screws serial interface Serial interface COM3 RS232 and COM4 9-pin D-sub connection, installed connector with 4-40 UNC retaining screws RS485 Ethernet...
Technical data and dimension sheets Cable Cable 8.3.1 Prefabricated communication cables SEW‑EURODRIVE offers the following prefabricated RS485/RS422 communication cables with 9-pole D-sub connector for connecting the operator panel to inverters and PCs: Cable type Part number Open end/conductor end 17975182 sleeve RJ10 17975190...
Page 43
Technical data and dimension sheets Cable Cable 17975190 Connection overview Cable Terminal Contact male Signal Terminal Conductor designation link Color \ imprint RS485 + WHOG 120 Ω RS485 - WHGN Housing Shielding (Outer) nc. 2.3.4.7.8.9 13892082187 Plug connector D-sub 9-pole, fe- RJ10 connector male Cable LIYCY-Pair, 2 × 2 × 0.14 or...
Page 44
Technical data and dimension sheets Cable 8.3.2 CAB150 adapter cable SEW‑EURODRIVE part number: 19500793 Use the CAB150 adapter cable for splitting the RS485 interfaces of the following oper- ator panels: Operator panels design (DOP11C-42, DOP11C-72, DOP11C-102, DOP11C-122, DOP11C-152). 30058211211 Operating Instructions – DOP11C Operator Panels...
Page 45
Technical data and dimension sheets Cable 30058208267 Operating Instructions – DOP11C Operator Panels...
Appendix Chemical resistance Appendix Chemical resistance 9.1.1 Plastic housing Frame and housing of operator panels in design ..1 (DOP11C-51, -71 and -101) are made of the plastics PC and ABS. The plastics can be exposed to the following sub- stances without any visible changes: Acetic acid 10% Nitric acid 10% Silicone oil...
Page 55
Appendix Chemical resistance 9.1.2 Aluminum housing Frame and housing of operator panels in design ..2 (DOP11C‑42, ‑72, ‑102, ‑122 and ‑152) are made of powder-coated aluminum. This powder coating can be exposed to the following substances for more than 24 hours without any visible changes: Acetic acid 10% Phosphoric acid 4% Citric acid 10%...
Page 56
Appendix Chemical resistance 9.1.3 Solvent resistance of the display The display can be exposed to the following substances for given time period the without any visible changes: Solvent Time period Acetone 10 min Isopropyl alcohol 10 min Toluene 5 h 9.1.4 Solvent resistance of the coating According to DIN ...
Condomínio Industrial Conpark montadora.rc@sew.com.br Caixa Postal: 327 13501-600 – Rio Claro / SP Joinville SEW-EURODRIVE Brasil Ltda. Jvl / Ind Tel. +55 47 3027-6886 Rua Dona Francisca, 12.346 – Pirabeiraba Fax +55 47 3027-6888 89239-270 – Joinville / SC filial.sc@sew.com.br...
Page 58
Ancienne Route Bonabéri Fax +237 233 39 02 10 P.O. Box sew@sew-eurodrive-cm B.P 8674 Douala-Cameroun Canada Assembly Toronto SEW-EURODRIVE CO. OF CANADA LTD. Tel. +1 905 791-1553 Sales 210 Walker Drive Fax +1 905 791-2999 Service Bramalea, ON L6T 3W1 http://www.sew-eurodrive.ca l.watson@sew-eurodrive.ca Vancouver SEW-EURODRIVE CO.
Page 59
Address list Colombia Assembly Bogota SEW-EURODRIVE COLOMBIA LTDA. Tel. +57 1 54750-50 Sales Calle 17 No. 132-18 Fax +57 1 54750-44 Service Interior 2 Bodega 6, Manzana B http://www.sew-eurodrive.com.co Santafé de Bogotá sew@sew-eurodrive.com.co Croatia Sales Zagreb KOMPEKS d. o. o.
Page 60
Graben SEW-EURODRIVE GmbH & Co KG Tel. +49 7251 75-0 Ernst-Blickle-Straße 1 Fax +49 7251-2970 76676 Graben-Neudorf Östringen SEW-EURODRIVE GmbH & Co KG, Werk Tel. +49 7253 9254-0 Östringen Fax +49 7253 9254-90 Franz-Gurk-Straße 2 oestringen@sew-eurodrive.de 76684 Östringen Service Competence Mechanics / SEW-EURODRIVE GmbH &...
Page 61
Address list Germany Saarland SEW-EURODRIVE GmbH & Co KG Tel. +49 6831 48946 10 Gottlieb-Daimler-Straße 4 Fax +49 6831 48946 13 66773 Schwalbach Saar – Hülzweiler dc-saarland@sew-eurodrive.de SEW-EURODRIVE GmbH & Co KG Tel. +49 7348 9885-0 Dieselstraße 18 Fax +49 7348 9885-90 89160 Dornstadt dc-ulm@sew-eurodrive.de...
Page 62
Ahofer Str 34B / 228 Fax +972 3 5599512 58858 Holon http://www.liraz-handasa.co.il office@liraz-handasa.co.il Italy Assembly Milan SEW-EURODRIVE S.a.s. di SEW S.r.l. & Co. Tel. +39 02 96 980229 Sales Via Bernini,12 Fax +39 02 96 980 999 Service 20020 Solaro (Milano) http://www.sew-eurodrive.it milano@sew-eurodrive.it...
Page 63
No. 95, Jalan Seroja 39, Taman Johor Jaya Fax +60 7 3541404 Service 81000 Johor Bahru, Johor sales@sew-eurodrive.com.my West Malaysia Mexico Assembly Quéretaro SEW-EURODRIVE MEXICO S.A. de C.V. Tel. +52 442 1030-300 Sales SEM-981118-M93 Fax +52 442 1030-301 Service Tequisquiapan No. 102 http://www.sew-eurodrive.com.mx Parque Industrial Quéretaro scmexico@seweurodrive.com.mx...
Page 64
Address list New Zealand Assembly Auckland SEW-EURODRIVE NEW ZEALAND LTD. Tel. +64 9 2745627 Sales P.O. Box 58-428 Fax +64 9 2740165 Service 82 Greenmount drive http://www.sew-eurodrive.co.nz East Tamaki Auckland sales@sew-eurodrive.co.nz Christchurch SEW-EURODRIVE NEW ZEALAND LTD. Tel. +64 3 384-6251...
Page 65
Tel. +386 3 490 83-20 Service UI. XIV. divizije 14 Fax +386 3 490 83-21 3000 Celje pakman@siol.net South Africa Assembly Johannesburg SEW-EURODRIVE (PROPRIETARY) LIMITED Tel. +27 11 248-7000 Sales Eurodrive House Fax +27 11 248-7289 Service Cnr. Adcock Ingram and Aerodrome Roads http://www.sew.co.za Aeroton Ext.
Page 66
Address list South Korea Busan SEW-EURODRIVE KOREA CO., LTD. Tel. +82 51 832-0204 28, Noksansandan 262-ro 50beon-gil, Fax +82 51 832-0230 Gangseo-gu, Busan, Zip 618-820 Spain Assembly Bilbao SEW-EURODRIVE ESPAÑA, S.L. Tel. +34 94 43184-70 Sales Parque Tecnológico, Edificio, 302 http://www.sew-eurodrive.es...
Page 67
Wellford, S.C. 29385 IGOrders@seweurodrive.com Additional addresses for service provided on request! Vietnam Sales Ho Chi Minh SEW-EURODRIVE PTE. LTD. RO at Hochim- Tel. +84 937 299 700 City inh City Floor 8, KV I, Loyal building, 151-151 Bis Vo huytam.phan@sew-eurodrive.com...
Index Index Adapter cables ............ 44 Nameplate ............ 13 Notes Designation in the documentation .... 5 CAB150 ............... 44 Meaning of the hazard symbols ....... 6 Cables Cable cross sections ........ 17 Cable ducts ............ 17 Operator panel Shielding and grounding......... 17 Connecting to inverter and PC .......