72. Offset
0
Backburn XX°F
73. Offset
0
Boiler
XX°F
74. Offset
0
Outdoor
XX°F
75. Offset
0
Internal
XX°F
76. Offset
0
Lambda 0.0% O2
77. Extra inp. as
Outdoor temp.
78. Outdoor temp.
controls:
YES
79. Outdoor Temperature
Average
5
80. External
Thermostat? NO
o
81. Coldest Day -4
F
82. Warmest Day +68
o
83. Boiler Low 140
F
o
84. Boiler High 185
F
85. Fall shaft se. PT100
Show Full Menu "menu" @
3 sec = Yes
Display status texts
JANFIRE AB
Version X.XX
Start-up underway
Try 1
3 min
Running 51.00 MBTU
Waiting...
Keep-alive
mm:ss
Defaults set
Release buttons
Saving in
memory
Heating up
Step 1 mm:ss
Stop
Waiting.
Shutdown
activated...
Now shut down
waiting
Wait! Cooling
down burner
Waiting for pellets
Janfire NH Burner Service Installation Manual 4.16.09 - Technical specifications are subject to change without prior
notice.
-100 – +100
-100 - +100
-100 - +100
-100 - +100
-100 - +100
Exhaust
NO-YES
5 - 15
NO/YES
o
(-40 – 50
F)
o
o
F
(14 – 68
F)
o
(140 – 176
F)
o
(149 – 194
F)
Type K
Start text at power up, shows program version
Shows that burner start-up try process underway, and time elapsed
Run mode, actual power level
Burner has reached set point
Shows time elapsed in maintenance mode
Default values have successfully been reset
Setting is being saved
Waiting to transition to run mode from maintenance, a manual stop or after
power failure.
When burner is stopped with "on/off" button. Restart by pressing on/off button
again. If start not possible: replace box.
Burner is shut down via function in User menu, ash scraper will be activated
when burner cooled down.
Burner is shut down.
Cooling burner bowl to reach limit value set in service menu 48
Waiting to fill up burner internal pellet hopper
Temperature calibration for drop shaft temperature sensor
Temperature calibration for boiler water temperature sensor
Temperature calibration for outdoor temperature sensor
Temperature calibration for internal control temperature sensor
Calibration adjustment for signal lambda sensor
Change input sensor. Select: Outdoor or Exhaust
Select boiler temperature controlled by outdoor temperature:
Select "YES" when using outdoor sensor.
Sets time for average outdoor temperature reading frequency
(min).
When "YES" is selected, a L4006A operating aquastat can be
installed on the brown wire (See pg. 37).
When "NO" is selected, a L4006A can not be installed. NO is
factory setting.
Stops heating curve on coldest day.
Starts heating curve on the warmest day of the heating season.
Sets boiler temp on the warmest day of the heating season.
Sets boiler temp for the coldest day of the heating season.
Defines type of drop shaft sensor. Other option: Type K.
(previous version sensor).
Allows user to view remaining parameters.
)
30(38