The outdoor unit installation

Connecting the cable to Outdoor Unit
• Remove the side panel or cover control for wiring connection.
• Use the cord clamp to fix the cord.
• Earthing work
- Case 1 :Terminal block of Outdoor Unit have
• Connect the cable of diameter 1.6mm
the control box and do earthing.
- Case 2 :Terminal block of Outdoor Unit don't have
• Connect the cable of diameter 1.6mm
as
and fasten with earth screw.
Power cord
terminal
Capacity 3.5 / 5 kW
CAUTION:
• The circuit diagram is not subject to change without notice.
• Be sure to connect wires according to the wiring diagram.
• Connect the wires firmly, so that not to be pulled out easily.
• Connect the wires according to color codes by referring the wiring diagram.
CAUTION:
following specifications.
Connecting cable
terminal
Cord clamp
Cover control
Tubing Cover
The Power cord connected to the unit should be selected according to the
mark.
2
or more to the earthing terminal provided in
mark.
2
or more, to the panel of control box, marked
Capacity 6 / 7 kW
The outdoor unit installation
Power cord
terminal
Connecting
cable terminal
Cord clamp
Cord clamp
* Make sure the rubber
bushes are Properly
used in knock-out holes
after connecting main
Power cable
Installation Manual 7