Download Print this page

Sealey STS104 Instructions page 2

Screwdriver torque digital 0-20nm 1/4” hex drive

Advertisement

4.
function Keys (fig.1.)
1. Press to turn the unit on and off.
2. Press to select the measurement mode between "track" and "peak". / Press
and hold the button for 2 seconds to select the units. / under setting mode, press
to increase the value to program pre-set torque.
3. under measure status, press to switch on and off the back light. / under
measure status, press and hold the button for 2 seconds to enter the setting
mode. / under setting status, press to memorize the setting value and quit setting
mode.
4. under measure status, press to Zero tare. / under measure status, press
and hold the button for 2 seconds to switch on and off the led lamp which is
at the front of the tool. / under setting mode, press to decrease the value to
program pre-set torque.
5. preparation
.
5.1.
install the new batteries.
5.1.1.
remove battery cover on the side of the screwdriver. Place batteries in battery compartment and replace cover.
5.2.
turning the tool on / off.
5.2.1.
Press "
" button to turn on. the buzzer sounds and on the display you can see all readouts at the same time for just a moment. then
wait the display will show " 0000 " on the screen.
5.2.2.
Press " " button again to turn off the electronic system.
5.3.
activating the "peak mode"
5.3.1.
After turning on the display, the default is in " tracK " mode, i.e. the real-time torque reached during operation will be displayed.
5.3.2.
during the " PeAK " mode, the torque screwdriver will record and display the present maximum value. When the force released, the
maximum value is shown on the display. Press "
and PeAK mode.
5.4.
turning the lcd Back light on/off.
5.4.1.
the lcd Back light can be turned on prior to or after programming the torque.
5.4.2.
in order to do this, press the "
5.5.
turning the led lamp on/off.
5.5.1.
the led lamp, at the front of the tool can be turned on prior to or after programming the torque.
5.5.2.
in order to do this, press and hold the "
5.6.
peak & track mode and units selection
5.6.1.
turn the torque screwdriver on and press "
shows "peak" on the left side of the screen.
5.6.2.
Press and hold "
5.7.
programming the pre-set torque value
5.7.1.
Press and hold "
the last programmed value will be shown on display, press the "
the value.
5.7.2.
once the target torque is select, press "
warning! if the pre-set torque exceed the 125% maximum torque value (20nm), the value will jump back to Zero. the pre-set has
failed. if the warning indication did not work, reset mode again. the last pre-set torque value will be shown on the screen. if no value
shows, it means the pre-set has failed. Please read the instruction manual again and follow the procedure of "Pre-set torque Value".
© Jack sealey limited
" button to turn on or turn off.
" button for 2 seconds to turn on or turn off.
" button switch between "trAcK" mode and "PeAK" mode. in "PeAK" mode, the display
" button for 2 seconds to select units between n.m / lbf-ft / lbf-in.
" button for 2 seconds to enter the setting mode, the display shows " set " on the screen. After 2 seconds, "0.00" or
" button to memorize and quit setting mode.
Original Language Version
fig.2
" button to zero the value or press "
" button to increase the value, or press the "
" button switch between trAcK mode
" button to decrease
sts104 | issue 1 15/05/17
fig.1
fig.3

Advertisement

loading