Daikin FTK18NMVJU Service Manual page 10

Removal procedure
Hide thumbs Also See for FTK18NMVJU:
Table of Contents

Advertisement

Electrical Box / Swing Motor
Step
6
Disconnect the
connector [S200].
7
Release the harnesses
from the 4 hooks and
the groove.
8
Disconnect the
connector [S6].
9
Release the harnesses
from the 2 hooks and
from the groove.
10 Remove the screw of
the electrical box.
8
Procedure
Right view
Groove
Hook
Groove
Hook
[S200]: fan motor
[S200]
Hook
(R24363)
[S6]: swing motor
[S6]
(R21510)
Electrical
box
(R22754)
Si041553EB