10.3 Termination

Function
AC Alarm
+24VDC OUT
+24V Battery input
(not used in this application)
230 VAC INPUT

10.4 Specifications

Maximum input voltage
Maximum output voltage
Operating temperature
range
Storage temperature
Power supply wires
Weight

10.5 Operation

There are no operator functions or controls apart from the ON/OFF switch on the outside of the
device.
Lethal single phase AC and DC voltages are present within the unit.
The unit must be fully isolate from the AC mains supply before removing the cover.

10.6 Maintenance

The power supply cannot be repaired in the field.
Input Fuses:
110/127V AC
Fuse T2A
220/ 237V AC
Fuse T1A
X-band 12kW Upmast Magnetron Transceiver
Chapter 10: Optional AC/DC power supply
Terminal Number
X2-1
X2-2
X2-3
X4-1
X4-2
X4-3
X5-1
X5-2
X5-3
X1-1
X1-2
X1-3
110/127V AC or 220/ 237V AC
160VA 50/60HZ
24V DC @ 170W
-15°C to +55°C, 93% relative humidity
-20°C to +70°C, 93% relative humidity
110V AC - 2 X 1.5mm
220V AC - 2 X 0.7mm
24V AC - 2 X 6.0mm
Note: The Absolute maximum voltage allowed on the battery input
is 32V.
5kg
WARNING
ELECTRICAL HAZARDS
HBK-2300-3 Issue 2
Page 36 of 40
Connection
N/C
Common
N/O
Ground
OV
+24VDC OUT
Ground
OV
+24VDC IN
Chassis/ Ground
Natural
Live
2
2
2