Optional Ac/Dc Power Supply; Installation; Grounding - KELVIN HUGHES X-band Installation Instructions Manual

12kw upmast transceiver
Table of Contents

Advertisement

10 Optional AC/DC power supply

Kelvin Hughes part number: 80119460
The optional AC to DC power supply ca be used where no ships DC power is
available to power the E70352 transceiver power supply.
10.1

Installation

DIMENSIONS
SUITABLE LOCATIONS
Ensure the unit is mounted in a location that allows proper routing and connection of cables.
Ensure that the unit is mounted in a compartment of suitable size.
It is important to check the unit's location to ensure it is correctly mounted and that all fastenings
are secure and tightened.
Make sure that the device will not be affected by electromagnetic field generators.
The chosen location should not be an area of high vibration.
The area should be free of dust.
The device should not be left in direct sunlight.

10.2 Grounding

The unit must be grounded to a tested and proven ground point. The earth connections must be
tested for conductivity using a high conductivity impedance meter such as a Megger or similar.
The system must NOT be operated or have AC power switched ON with Earth/ Grounding points
X-band 12kW Upmast Magnetron Transceiver
Chapter 10: Optional AC/DC power supply
CAUTION
disconnected.
HBK-2300-3 Issue 2
Page 35 of 40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents