OPERATION
INVERTER DC PULSED
TUNGSTEN ARC WELDER
ATTENTION:
Be sure that all installation operation, maintenance and repair
procedures are preformed only by qualified individuals.
Read this operators manual completely before attempt to use
this equipment.
Save this manual and keep it well for quick reference pay more attention to the
safety instructions.
MANUAL
TIG200P

Advertisement

Table of Contents
loading

Summary of Contents for Hanshen TIG200P

  • Page 1 OPERATION MANUAL INVERTER DC PULSED TUNGSTEN ARC WELDER TIG200P ATTENTION: Be sure that all installation operation, maintenance and repair procedures are preformed only by qualified individuals. Read this operators manual completely before attempt to use this equipment. Save this manual and keep it well for quick reference pay more attention to the...
  • Page 2: Table Of Contents

    CATALOGUE 1. Characteristics & applications…………………………………….2 2. Safety attention……..……………………………………………...2 3. Range of welding parameters ……………………………………..4 4. Installing and connecting…… …………………………………..4 5. Prepare for welding………………………………………………..7 6. Weld-operating ………………….………………………………..10 7. Daily maintain & check…………………………………………...12 8. Trouble shoot…………………….…………………………….….12 …………………….……………………………….16 9. Circuit diagram...
  • Page 3: Characteristics & Applications

    1. CHARACTERISTICS & APPLICATIONS This arc welder HT200P can invert the working frequency DC of 50Hz into the high frequency of 25KHZ, with built-in MOSFET from IR company and the application of PWM technique, and reduces voltage, rectifies current and outputs a high DC power source fitting for welding. Its functions include DC MMA, DC TIG welding and pulsed TIG welding.
  • Page 4 To avid from the injure and hurt by smoke and bad gas, the exhaust equipments ought to be installed or useful breath apparatus should be used, depending on your rules. (4). Don’t open up the welder or use it in open position. B: Av o id bu rn in g or fi re (1).Avoid burning from over-heat: Keep the welder from the wall for more than 30cm and from combustible articles for more than...
  • Page 5: Range Of Welding Parameters

    3. RANGE OF WELDING PARAMETERS table 1. the range of welding parameters Model Parameter TIG200P Item Rated input voltage(V) 1-Phase,220V±10 %, 50/60Hz Rated input current(A) 17.5 Rated input capacity(KVA) Rated output current(A) Rated load voltage(V) 26.4 Idle voltage(V) ≤113 ≤113...
  • Page 6 ,when weld is operated in close space. (4 ). PO W E R SUPPL Y EQ UI PM ENT & CON NE CT IO NS table 2. power supply equipment & connections mode TIG200P Input voltage(V) 1-phase,220±10% Capability (KVA) ≥7.5 Input cable(m ㎡)
  • Page 7 p i c t u r e 1 . c o n n e c t i o n f o r T I G w e l d i n g p i c t u r e 2 . c o n n e c t i o n f o r M M A w e l d i n g...
  • Page 8: Prepare For Welding

    5. PREPARE FOR WELDING p i c t u r e 3 F R O N T P A N E L p i c t u r e 4 R E A R P A N E L (1).WELDER CONNECTION Connect the welder according to the pictures1-3 and the requirements in 4.6 for welding.
  • Page 9 List3、reference of tungsten All o we d ran ge of cu rre nt ( A) Current range tungsten dia. Tho r iu m tu n gs t en , (mm) Pure tun gs t en cer ium tun gs t en 1.
  • Page 10 (3).TORCH Ins ta l l th e to rc h acc o rd i ng to li s t 5. P i c t u r e 6 . s t r u c t u r e o f t o r c h (4).WELDING MODE SELECTION &...
  • Page 11: Weld-Operating

    current”, it is always selected in a lesser value which can protect arc not breaking). Open up the valve of argon bottle and adjust the flowmeter to the needed value. Set post flow gas time: Adjusting post flow gas time means that argon gas can be turned off later for a proper time after welding being finished and arc being broken.
  • Page 12 Pulsed TIG welding P i c t u r e 7 . p u l s e r e l a t i o n IP—summit current Ib—base current tp—width time of summit current T—period of pulse , it can be adjusted among 0.5~200Hz. D=...
  • Page 13: Daily Maintain & Check

    7. DAILY MAINTENANCE & EXAMINATION Regular maintenance and examination can guarantee the machine in good work condition. When the machine is not in use for a long time, it should be regularly and periodically (once two months) examined in the state of electrification in order to ensure the machine dry and avoid the components disabled or the parameters changed.
  • Page 14 8.TROUBLES EXAMINATION & REPAIR The overhauler can examine and repair the machine according to table 8 after examining it on the base of list 7. Please contact the seller or the producer if the malfunctions still have not been eliminated. ATTENTION: 1.
  • Page 15 Lis t 8 Troubles Possible causes Eliminate methods Fun does not work after Power does not exist Check input power turning on the power switch Power switch is broken Change power switch Disconnection inside machine Check inside connecting The fun is broken Change fun No voice of Torch switch or “arc control”...
  • Page 16 Troubles Possible causes Eliminate methods No argon flows out after Switch of argon bottle or Open up these two switches pressing the torch switch flowmeter doesn’t open up Gas tube is jammed or broken Check tube Gas valve is broken Change valve Can’t close relay J3(4123) in Change relay J3(4123) or board...
  • Page 17: Circuit Diagram

    9. CIRCUIT DIAGRAM...