3.3

Mounting for corner and pole mount

Follow the steps below to mount the device to a corner/mast:
1. Use the universal support as template and draw the bore holes on the corner / mast.
2. Drill the holes with a suitable device.
3. Insert the suitable anchors in the holes. (Anchors are not supplied with the device.)
4. Install the universal support to the corner / mast.
5. Mount the device to the universal support using the screws (M4). (Screws are not
supplied with the device.)
Figure 3-3
Note
If drilling is not possible, you can also fasten the universal support to the given position using
with cable ties, for example.
3.4

Ethernet

When installing and connecting the Ethernet connection, observe the applicable general
conditions and their legal basis.
The Ethernet connection is connected to the Ethernet socket of the device. The cable must
be connected to the RJ45 plug before connection to the socket.
For the supply voltage of the device over PoE, a corresponding infrastructure such as PoE
injector or PoE switch is required.
By default, DHCP is enabled with the Locating Manager server address 192.168.1.10.
SIMATIC RTLS4030G
Operating Instructions, 06/2020, C79000-G8976-C515-03
Universal support - all dimensions specified in millimeters.