Mode Photocell IP54 Outdoor Wall Light
Safety Warnings
• This product is suitable for connection to 240V~50Hz supply, outdoor and bathroom use.
• Before installing your light fitting always switch off the mains supply and remove the appropriate fuse or
switch off the appropriate circuit breaker before commencing installation.
• It is recommended that this light be installed by a qualified electrician in accordance with current IEE Wiring
Regulations and Building Regulations (Part P).
• This is a Class I fitting, and must be connected to
requirements of the fitting.
• Never fit bulbs of a higher wattage than those specified on the label (as these may cause overheating and
damage the fitting).
• This product contains delicate parts. Take care during installation and maintenance to avoid breakages
• If you are in any doubt about your competence please consult a qualified electrician.
• If any modification is made it will invalidate the warranty and may render the product unsafe.
• If the glass or diffuser is broken or cracked it must be replaced, please consult your retailer. This is the
symbol which denotes this requirement:
Outdoor Use:
• Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm2
(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it
must come out of the flat surface of the wall or steps in line with the entry to the fitting.
• Except where installed in a conduit or duct which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as
a protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables,
conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable
disturbance of the ground.
Bathroom Use:
• This light may also be installed in "Zones 1 and 2 and Outside Zones" of a bathroom where water jets are
not used for cleaning purposes. These zones are referenced in BS 7671: 2008 "Requirements for Electrical
Installations", IEE Wiring Regulations 17th Edition. All dimensions must be checked in conjunction with the
Regulations - Please see diagram below.
ZONE
1
0.6m
2.25m
ZONE
Care Information
Allow 10 minutes to cool before replacing, adjusting or cleaning. Clean with a dry cloth only. Do not use liquid
or abrasive cleaners on this product.
Endon Lighting, LS9 0SE
INSTRUCTION MANUAL
Ceiling
OUTSIDE ZONES
0.6m
2
Earth. The terminal blocks are supplied according to
• The supply circuit must be protected by an RCD. If installed
in a bathroom an RCD must be used/ OR the casing
of the light must be connected to the "Supplementary
Equipotential Bonding" points in the bathroom.
• An electrician must be consulted if in any doubt about
your own competency or meaning of bathroom "Zones" or
"Equipotential Bonding".
56410-ModePhotocell-WB 20150930