3.2
Installation Instructions for Hazardous-Location EMC Cable Glands
Power supply cables for the Ex e Ethernet and the RS-485 or TTY Ex e data interface, the Ex i
keyboard, and the Ex i scanner must be shielded to ensure sufficient immunity to interference
(EMC). Connect the cable shielding to the VisuNet RM/PC according to the following
installation instructions:
18
Step 1
Isolate the cable.
Expose the braid.
Remove the braid and insulation little by
little.
With thin cables, the braid can be folded
back over the insulation sheath.
Insert the cable into the gland until the
braid reaches the contact point.
Tighten the cable gland.
Step 2
Guide the cable through the lock nut.
Guide the cable into the terminal insert.
Fold the braid over the insert.
The braid must overlap the O-ring by about
2 mm
Step 3
Fit the terminal insert into the intermediate
gland.
Assemble the cable gland.
Internal view of the assembled cable gland.