Product Description and Specification:
*** For indoor use only***Specification:
Protocol: Z-Wave™ (ZM5202)
Frequency Range: 865.22MHz (ZD2112IN-5)
868.10MHz (ZD2112MY-5)
868.42MHz (ZD2112EU-5)
869.00MHz (ZD2112RU-5)
908.42MHz (ZD2112US-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Battery: AAA Battery * 2PC
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Notification V4 Type:
SWITCH TYPE
Reed Switch
Notification Type
Tamper Switch
Reed Switch
Event
Tamper Switch
V1 Alarm:
Switch Type
Reed Switch
Alarm Type
Tamper Switch
Alarm Level
Close: 0x00; Open 0xFF
Introduction
Thanks for choosing the Vision's wireless door/window
sensor of the home security device. This sensor is a Z-Wave
™ enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any
Z-Wave™ enabled network and it's security framework. Every mains
powered Z-Wave enabled device acts as a signal repeater and multiple
devices result in more possible transmission routes which helps eliminate
"RF dead-spots"
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be
used with it regardless of the manufacturer, and ours can also be used in
other manufacturer's Z-Wave™ enabled networks. One unique design
ZD2112 is sufficient for one sliding window/door no matter what the sliding
direction is right or left. This sensor monitors door/window and send
Z-Wave™ signal when door or window is opened and closed. When the
device is secure included into Z-Wave network, above communication will
be encrypted, ZD2112 supports SECURITY S0 / SECURITY S2
UNAUTHENTICATED / SECURITY S2 AUTHENTICATED.
Operation
Opening/Closing the door/window to separate the magnet from the
1
sensor will send signal to any association nodes accordding to the
Status/Signal table on page 2 and the LED will flash once.
Normal operation, the LED is off.
2
If the cover of sensor is removed, the tamper switch will send signal
3
according the Status/Signal table, and the LED will go solid. Then red
LED will go off after 10 seconds.
4
ZD2112 will send signal according the status / signal table after closing
the rear cover back 2 seconds..
916.00MHz (ZD2112IL-5)
920~923MHz (ZD2112KR-5)
919.80MHz (ZD2112HK-5)
922~926MHz (ZD2112JP-5)
921.42MHz (ZD2112BR-5)
Z-Wave S2 Support Command Classes :
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_BATTERY
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
STATUS
0x06
0x07
Close: 0x17, Open: 0x16
Close:0x00; Open:0x03
Status
0x06
0x07
ZD2112-5 V0
1061023
Installation & Operation Manual
ZD2112IN-5
ZD2112MY-5
ZD2112EU-5
ZD2112RU-5
ZD2112US-5
ZD2112IL-5
ZD2112KR-5
ZD2112HK-5
ZD2112JP-5
ZD2112BR-5
Federal Communications Commission Statement
This equipment has been followed to comply with Part 15 of the FCC
Rules. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction,
may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try and correct the interference by one of the
following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesirable operation.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate
this equipment.
Limited Warranty
Vision Guarantees that every wireless door/window sensor is free from
physical defects in material and workmanship under normal use for one
year from the date of purchase. If the product proves defective during this
one-year warranty period, Vision will replace it free of charge. Vision does
not issue any refunds. This warranty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to: (1)
damage to units caused by accident, dropping or abuse in handling, or any
negligent use; (2) units which have been subject to unauthorized repair,
taken apart, or otherwise modified; (3) units not used in accordance with
instruction; (4) damages exceeding the cost of the product; (5) transit
damage, initial installation costs, removal cost, or reinstallation cost. For
information on addional devices, plesae visit us at
www.visionsecurity.com.tw
www.visionsecurity.com.tw

Advertisement

loading

Summary of Contents for Vision ZD2112IN-5

  • Page 1 If the product proves defective during this If the cover of sensor is removed, the tamper switch will send signal one-year warranty period, Vision will replace it free of charge. Vision does according the Status/Signal table, and the LED will go solid. Then red not issue any refunds.
  • Page 2 Product Package Content: Installation & Battery Operation manual Adhesive tape for sensor ZD 2112-5 sensor Magnet Installation Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to the installation guide of Z-Wave™ Interface Controller before installing ZD2112. Auto Wake Up: Use “Wake Up”...

This manual is also suitable for:

Zd2112my-5Zd2112eu-5Zd2112ru-5Zd2112us-5Zd2112il-5Zd2112kr-5 ... Show all