6. Fault finding:

a) Unit does not work properly anymore:
If the unit has run for some time and will
not start or does not run properly any
more, it might be due to the following:
Air intake valve is dirty (illus. 15+16
page 39).
Swirl vane (illus.23 page 46) is
covered with residues.
Mixing chamber and mixing tube of
resonator is covered with residues
(illus. 19 page 41).
End of resonator at fog solution socket
is blocked by residues (illus. 17 page
39).
Solution line is clogged
pos.3
illus. 21
SP list page 70
(illus. 21
43
72