Measurement Functions; Power Quality Functions - ABB REF 54 Series Technical Reference Manual, General

Feeder terminal
Hide thumbs Also See for REF 54 Series:
Table of Contents

Advertisement

1MRS750527-MUM
5.1.1.2.
Table 5.1.1.2-1 Measurement functions available for REF 54_
Function
ANSI device no. IEC symbol
2)
AI1
MEAI1
2)
AI2
MEAI2
2)
AI3
MEAI3
AI4
2)
MEAI4
2)
AI5
MEAI5
2)
AI6
MEAI6
2)
AI7
MEAI7
AI8
2)
MEAI8
2)
AO1
MEAO1
2)
AO1
MEAO2
2)
AO3
MEAO3
AO4
2)
MEAO4
MECU1A
Io
MECU1B
Io_B
MECU3A
3I
2)
3I_B
MECU3B
DREC
1)
MEDREC16
MEFR1
f
MEPE7
PQE
MEVO1A
Uo
2)
Uo_B
MEVO1B
MEVO3A
3U
2)
3U_B
MEVO3B
5.1.1.3.
Table 5.1.1.3-1 Power quality functions available for REF 54_
Function
ANSI device no. IEC symbol
1)
PQ 3Inf
PQCU3H
1)
PQ 3Unf
PQVO3H
2)
PQ 3U<>
PQVO3Sd
Feeder Terminal
Technical Reference Manual, General

Measurement functions

Description
AI1
General measurement 1 / analog input on RTD/analog module
AI2
General measurement 2 / analog input on RTD/analog module
AI3
General measurement 3 / analog input on RTD/analog module
AI4
General measurement 4 / analog input on RTD/analog module
AI5
General measurement 5 / analog input on RTD/analog module
AI6
General measurement 6 / analog input on RTD/analog module
AI7
General measurement 7 / analog input on RTD/analog module
AI8
General measurement 8 / analog input on RTD/analog module
AO1
Analog output 1 on RTD/analog module
AO1
Analog output 2 on RTD/analog module
AO3
Analog output 3 on RTD/analog module
AO4
Analog output 4 on RTD/analog module
Io
Neutral current measurement, stage A
Io_B
Neutral current measurement, stage B
3I
Three-phase current measurement, stage A
3I_B
Three-phase current measurement, stage B
DREC
Transient disturbance recorder
f
System frequency measurement
PQE
Three-phase power and energy measurement
Uo
Residual voltage measurement, stage A
Uo_B
Residual voltage measurement, stage B
3U
Three-phase voltage measurement, stage A
3U_B
Three-phase voltage measurement, stage B
1) These functions are only supported in the feeder terminal revisions of Release 1.5 or later.
2) These functions are only supported in the feeder terminal revisions of Release 2.0 or later.
Refer to Section "Revision identification" on page 105 for more information.

Power quality functions

Description
PQ 3Inf
Current waveform distortion measurement
PQ 3Unf
Voltage waveform distortion measurement
PQ 3U<>
Short duration voltage variations
1) These functions are only supported in the feeder terminal revisions of Release 2.0 or later.
2) This function is only supported in the feeder terminal revisions of Release 3.5 or later
Refer to Section "Revision identification" on page 105 for more information.
REF 54_
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ref 541Ref 543Ref 545

Table of Contents