Specifications
Specifications
Environmental
Power Supply
Power Consumption
Output Signals
Relay Outputs
Response Time
Range of Detection
Cone of Detection
Storage Temperature Range
Internal Battery Cell
Weight
Dimensions
Ingress Protection
Accessories
Compliance to Standards
Safety Approvals
-55°C to +75°C (-67°F to +167°F); 0 % to 100 % RH condensing
24 Vdc nominal (18 Vdc to 32 Vdc)
4 W for ambient operating temperature >= -30°C
15 W for ambient operating temperature < -30°C (heater is active)
4-20 mA with HART, Fault relay, Alarm 1 relay, Alarm 2 relay, Modbus, Bluetooth® (range up to 15 m, depends on
mobile device and environmental conditions)
Max. 32 Vdc/ac, max. 2 A resistive load
Sensor response 1 s; Programmable Verification time from 1 s to 600 s
18 kHz to 70 kHz; 40 dB to 140 dB
Typically 20 m on-axis radius (background noise dependent); +/- 90 degrees solid angle from on axis to 6 dB down
-55°C to +75°C (-67°F to +167°F)
TLH-2450, 10-year lifetime (replaced only by authorized service)
Searchzone Sonik: 6.1 kg (13.5 lbs)
Standard Adjustable Mounting Bracket: 2.9 kg (6.4 lbs) Stainless Steel
Large Adjustable Mounting Bracket (optional): 3.5 kg (7.7 lbs) Stainless Steel
Searchzone Sonik: 103 mm dia x 235 mm x 179 mm
Standard Adjustable Mounting Bracket: 165 mm x 165 mm x 127 mm
Large Adjustable Mounting Bracket (optional): 210 mm x 210 mm x 127 mm
IP 66 / 67 (Type 4X, in accordance with NEMA 250)
Resistance to salt mist and sulphuric atmosphere (15-60 minutes exposure to salt air/mist; 15-60 minutes to
sulphuric atmosphere)
Large Adjustable Mounting Bracket
Stainless Steel Sunshade
Searchzone Sonik Test Unit
Hazardous Area Mobile Phone
Searchzone Sonik App
Core Approvals:
EN 50270: (EMC)
IEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EU
IEC/EN/UL/CSA 61010 (Electrical Safety)
FCC / IC
RoHS, China RoHS
ATEX: DEMKO 17 ATEX 1866 Rev.0
II 2 GD
Ex db ia IIC T4 Gb (flameproof Ex d version)
Ex tb IIIC T85°C Db (flameproof Ex d & increased safety Ex e versions)
Ex db eb ia IIC T4 Gb (Increased safety Ex e)
Tamb -55°C to +75°C (-67°F to +167°F)
Um = 250 Vrms
cULus
Class I, Div 1, B, C & D
Class II/III, E, F & G
Tamb -55°C to +65°C
Class I Zone 1 AEx db ia IIC Gb T4 (USA)
Class I Zone 1 Ex db ia IIC T4 Gb (Canada)
IECEx: IECEx ULD 17.0016 Issue 0
Ex db ia IIC T4 Gb (flameproof Ex d version)
Ex tb IIIC T85°C Db (flameproof Ex d & increased safety Ex e versions)
Ex db eb ia IIC T4 Gb (Increased safety Ex e)
Tamb -55°C to +75°C (-67°F to 167°F)
CU TR-Ex (Russian Customs Union) - contact Honeywell for availability
Inmetro
China Ex
Marine Approvals: Type approved to DNV, BV, Lloyds, ABS - Temp B, Humidity B,
Vibration A & C, EMC B