TUNER
In the tuner screen, you can operate knobs [1]–[3] to set the following
parameters.
[1] knob
Parameter
Value
Explanation
435–
PITCH
Adjusts the tuner's reference pitch.
445Hz
[2] knob
Parameter
Value
Explanation
select the input signal that is detected by the tuner.
MIC
Shows the pitch of the mic input.
SOURCE
INST
Shows the pitch of the guitar input.
INST&M
Shows the pitch of both the guitar and mic.
[3] knob
Parameter
Value
Explanation
Specify how the vocal sound is output while you're using the
tuner.
BYPASS
Output with the effects off
VOCAL OUT
DRY
Output with ENHANCE applied
LEAD
Output with ENHANCE and PITCH CORRECT applied
MUTE
Output is muted
MIDI
Here you can make MIDI-related settings.
Parameter
Value
Ch.1–Ch.16,
RX CH
OFF
OMNI
OFF, ON
Ch.1–Ch.16,
TX CH
RX, OFF
Selects the tempo clock input that is used for synchronization.
INT
USB
MIDI
SYNC
AUTO
Selects the source of the realtime messages that are
transmitted from the MIDI OUT connector or the USB
port.
REALTIME
INT
MIDI
PC IN
OFF, ON
PC OUT
OFF, ON
BANK OUT
MSB, M+L
THRU
OFF, ON
DEVICE ID
1–32
MENU
Explanation
Specifies the receive channel.
If this is "OFF, " MIDI messages are not
received.
If this is "ON, " MIDI messages are
received regardless of the channel.
* Messages are not received if RX CH
is "OFF. "
Specifies the transmit channel.
If this is "OFF, " MIDI messages are not
transmitted.
Synchronizes to the internal tempo.
Synchronizes to the tempo from the
USB port.
Synchronizes to the tempo from the
MIDI IN connector.
Normally synchronizes to the internal
tempo, but if MIDI clock is being input
from the MIDI IN connector or the USB
port, the tempo is synchronized to MIDI
clock (AUTO).
If the VE-500 is a slave device, choose
the "AUTO" setting.
Internal realtime messages are the
source.
Realtime messages from the MIDI IN
connector are the source.
Specifies whether program changes are
received.
Specifies whether program changes are
transmitted.
Specifies the bank select message that
is transmitted simultaneously with the
program change.
If you select MSB, only MSB (CC#0) is
transmitted. If you select M+L, both MSB
and LSB (CC#32) are transmitted.
* The VE-500 itself does not use the
received LSB.
Specifies whether MIDI messages
received at the MIDI IN connector are
output from the USB port.
When using the editor, specify the
device ID that you're using.
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9000-0046-0816

Table of Contents