Starter Selection - Siemens 72G Series Setup Manual

For hydraulic elevator pump motors
Table of Contents

Advertisement

s

Starter Selection

Table 1: In Delta, 200 – 460 Volt starter ratings
HP @
HP @
200V
5
7.5
10
15
In Delta
20
Configuration
25
30
40
50
75
Table 2: In Delta, 460 - 575 Volt starter ratings
HP @
460V
15
25
30
40
In Delta
50
Configuration
60
75
100
125
________________________________________________________________________________
4
Siemens Energy & Automation, Inc. 3333 Old Milton Parkway Alpharetta, GA 30202
HP @
Rated
230V
460V
Current
(Amps)
7.5
15
22
10
25
35
15
30
42
20
40
55
25
50
68
30
60
80
40
75
105
50
100
130
60
125
156
100
-
252
HP @
Rated
575V
Current
(Amps)
20
22
30
35
40
42
50
55
60
68
75
80
100
105
125
130
150
156
Overload
Current Limit
Range
Range
(Amps)
(Amps)
7 - 27
26 – 94
12 - 44
41 - 148
14 - 53
49 - 179
18 - 69
64 - 234
22 - 85
79 - 289
26 - 100
93 - 340
35 - 131
121 - 447
43 - 163
151 - 553
52 - 196
181 - 663
83 - 315
292 - 1071
Overload
Current Limit
Range
Range
(Amps)
(Amps)
7 - 27
26 - 94
12 - 44
41 - 148
14 - 53
49 - 179
18 - 69
64 - 234
22 - 85
79 - 289
26 - 100
93 - 340
35 - 131
121 - 447
43 - 163
151 - 553
52 - 196
181 - 663
Manufacturer
Catalog
Number
72EG34AFP
72GG34AFP
72HG34AFP
72JG34AFP
72KG34AFP
72LG34AFP
72MG34AFP
72NG34AFP
72PG34AFP
72RG32AFP
Manufacturer
Catalog
Number
72EG35AFP
72GG35AFP
72HG35AFP
72JG35AFP
72KG35AFP
72LG35AFP
72MG35AFP
72NG35AFP
72PG35AFP

Advertisement

Table of Contents
loading

Table of Contents