Download Print this page

Honeywell AIRVISOR 2 Instructions Manual page 8

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
Minimum Supply Pressures at the inlet of compressed air supply hose:
Supply
Hose length
Hose bore
(m)
(mm)
8
3.5
7.5
10
Maximum Supply Hose Length 10 metres.
For DAVK-0001E and DMAK-0021E, if the warning whistle sounds at any time during the operation of the
auxiliary tool or spraygun, increase the input pressure until it stops. This ensures that there is sufficient
air reaching the headpiece and that your safety is maintained.
TECHNICAL INFORMATION
Certification / Approval
Standard / Compliance
Nominal Protection Factors
Visor:
Chemical resistant
Impact resistant
Manufacturer's Minimum Design Flow Rate
Maximum Flow Rate
Operating Pressure
Maximum Operating Temperature
Carbon Cartridge
PROTECTION FACTORS
An assigned Protection Factor (APF) of 40 means that the respirator can be used in areas of contamination up to 40 X the Workplace Exposure Limit.
In other geographical areas, please refer to national or regional regulations or guidelines which modify the value of the protection factor
that you are allowed to use when selecting respiratory protection.
AIRVISOR RESPIRATOR SYSTEMS
Article No.
Part No.
1013932
DAVK-0001E
1013934
DAVK-0003E
1013935
DAVK-0004E
1013938
DMAK-0021E
1013939
DMAK-0023E
1013980
DMAK-0024E
1013983
DAWK-4001E
1013987
DAWK-4011E
1765058
DAVK-0001E-DAC
1765059
DAVK-0003E-DAC
1765060
DAVK-0004E-DAC
1765061
DMAK-0021E-DAC
1765062
DMAK-0023E-DAC
1765063
DMAK-0024E-DAC
1765064
DAWK-4001E-DAC
1765065
DAWK-4011E-DAC
Supply Pressure in bars (psi)
DAVK-0001E
DAVK-0003E, 0004E
DMAK-0021E
DMAK-0023E, 0024E
DAWK-4001E, 4011E
5.3 bars
(77 psi)
5.4 bars
(79 psi)
5.5 bars
(80 psi)
CE Approved (CE 0194)
EN14594:2005 (Light Duty Class A)
Class 3 = 200
Class 4 = 2,000 DAVK & DMAK Models
EN 166.2.F
EN 166.2.B.9
260 l/min
290 l/min
4.5 bars (61 psi) to 7.0 bars (102 psi)
35°C
Replace after 1,000 hours, or
If odour is detected inside headpiece
Description
Airvisor 2 Paint Spraying Kit
Airvisor 2 Chemical Kit
Airvisor 2 Industrial Kit
Airvisor 2 MV Paint Spraying Kit
Airvisor 2 MV Chemical Kit
Airvisor 2 MV Industrial Kit
Airvisor 2 FV-Series Welding Kit
Airvisor 2 W-Series Welding Kit
Airvisor 2 Paint Spraying Kit double action connector
Airvisor 2 Chemical Kit double action connector
Airvisor 2 Industrial Kit double action connector
Airvisor 2 MV Paint Spraying Kit double action connector
Airvisor 2 MV Chemical Kit double action connector
Airvisor 2 MV Industrial Kit double action connector
Airvisor 2 FV-Series Welding Kit double action connector
Airvisor 2 W-Series Welding Kit double action connector
4.5 bars (61 psi)
4.6 bars (63 psi)
4.7 bars (64 psi)
DAWK models
EN-3