WARNING! POSSIBLE RISK OF INJURY TO EYES AND SKIN.
• Hazardous optical radiation may be emitted from the light source. Do not look
at an operating lamp. It may be harmful to the eyes.
• UVC is emitted from the light source. Eye or skin irritation may result from
exposure. Use appropriate shielding.
• IR may be emitted from the light source. Do not look at operating lamp.
CAUTION!
• To avoid eyes and skin exposure to UV light, it is forbidden for animals, plants
and all personnel to be present when the UV lamp is on.
• Always disconnect mains supply before removing any fixture covers.
• Keep this device away from rain and moisture.
QUICK START GUIDE
UVP36
www.goldenseauv.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVP36 and is the answer not in the manual?

Questions and answers

Summary of Contents for GOLDENSEA UV UVP36

  • Page 1 QUICK START GUIDE UVP36 WARNING! POSSIBLE RISK OF INJURY TO EYES AND SKIN. • Hazardous optical radiation may be emitted from the light source. Do not look at an operating lamp. It may be harmful to the eyes. • UVC is emitted from the light source. Eye or skin irritation may result from exposure.
  • Page 2 Thank you for purchasing a GOLDENSEA UV product. This manual is a quick operation guide to get you started. For more information, please always refer to the full version user manual provided. Before unpacking, please check and be sure that the package is in good condition with no damage on the carton during transportation.
  • Page 3 • For safety reasons, the device was designed with a motion sensor: if the working device detects any movement within 3m, it will immediately deactive and a continuous audible dual beep and flashing red and green LED indicator lights will engage. •...
  • Page 4 Guangzhou Haoyang Electronic Co., Ltd. E-mail: support@goldenseauv.com; Tel: +86 20 3996 6388 Addr: No.109 Haiyong Road, Shiji Town, Panyu Zone, Guangzhou, China. 511450...
  • Page 5 UVP36 USER MANUAL KEEP THIS MANUAL FOR FUTURE NEEDS...
  • Page 6: Table Of Contents

    Thank you for purchasing a GOLDENSEA UV product. You have acquired a powerful and versatile device. We are confident that you will be satisfied with our excellent products and service. For your own safety, please read this user manual carefully before installing and operating the device.
  • Page 7 www.goldenseauv.com Voltage Input: AC 100-120V~, 50/60Hz; AC 220-240V~, 50/60Hz Power: 45W; Product Size: 165x165x451mm This device is for household use, applications such as kitchen, bedroom, study, living room, etc.. It shall only be used by adults who are capable of operating this device by following this user manual, and keep children, pets and plants away from the disinfection area before operating.
  • Page 8: Manual Operation (Control Panel)

    www.goldenseauv.com 1. Manual Operation (control panel) 1) Close all the doors and windows. 2) Plug-in and power on, unlock the product by long pressing the Start touch key < > and the Lock touch key < > on the device for 3 seconds until there is a beep. 3) Select time setting <15 mins>, <30 mins>...
  • Page 9: Motion Sensor Operation (If The Lamp With Motion Sensor)

    www.goldenseauv.com Start 3. Motion Sensor Operation (if the lamp with Motion Sensor) 1. Turn on the UV lamp, select the disinfection time and start, leave the room, after 2 minutes alarming (Di….Di…Di….), the UV lamps will switch on automatically, the motion sensor will be activated.
  • Page 10: Notes

    www.goldenseauv.com 5. Notes 1. Put the UV lamp on a height of 0cm-400cm to get the best disinfection effect. Please do not put the lamp higher than 400cm, as the Motion Sensor cannot detect perfectly. 2. The surface of the lamp should be kept clean. 3.
  • Page 11 www.goldenseauv.com Avertissement – RISQUE BLESSURES WARNING – RISK OF PERSONAL INJURY CORPORELLES THIS EQUIPMENT IS DESIGNED FOR CET ÉQUIPEMENT EST CONÇU POUR ÊTRE USE WITH GERMICIDAL LAMPS OR UV UTILISÉ AVEC DES LAMPES GERMICIDALES OU SOURCES AND MUST BE INSTALLED DES SOURCES UV ET DOIT ÊTRE INSTALLÉ...
  • Page 12: Product Overview

    www.goldenseauv.com 8. Product Overview 1) Buzzer 2) Start - touch key 3) Lock - touch key 4) 15 mins - touch key 5) 30 mins - touch key 6) 60 mins - touch key 7) Cap 8) UV Tube 9) Lamp Tube Safety Catch 10)Power Cable 9.
  • Page 13: Replacing The Uv Tube

    www.goldenseauv.com 10. Replacing The UV Tube To maintain the sterilizing efficacy, the UV tube needs to be replaced after 9,000 hours of use. Steps: 1. Wait for UV tube to cool down (to avoid scalding) after switching off the device. 2.
  • Page 14: Features

    www.goldenseauv.com 1. The UV tube is the core of the product, it should be replaced after 9000 hours of use to maintain the germicidal efficacy. 2. The UV tube is defected if it flashes, please contact your local dealer or our customer service to order a new UV tube.
  • Page 15: Cleaning And Maintenance

    www.goldenseauv.com • UVC wavelength: 253.7nm • Radiation intensity in 200mm distance: 1933.4uw/cm² Product Type Household Ultraviolet disinfection light Weight Net weight: 0.77 kg Accessories List: UV Tube Included Remote Control Included (battery type: CR2025) UV Glasses Optional (protective eyewear) UV Irradiance Meter Optional 13.