Roto Safe Eneo Series Manual

Roto Safe Eneo Series Manual

Advertisement

Quick Links

Roto Safe Eneo
Roto Safe
Eneo
Note
Incorrect installation, maintenance or
operation can lead to hazardous situations.
This extract is not a replacement for complete
documentation. Failure to observe this
documentation discharges the hardware
manufacturer from their liability.
Note the complete installation, mainte-
u
nance and operating instructions (IMO).
The complete documentation for this extract is as
follows:
Roto Safe Eneo installation instructions:
C | CC | CF: IMO_438
Control Unit: IMO_288
Roto Safe Eneo brief instructions:
Power supply unit specifications (third-party
product): SUG_3
General information: SUG_9, SUG_10
Roto Safe Eneo: IMO_310
DANGER
Risk of death caused by electric
shock
Current can lead to fatal injuries.
Installation and maintenance work may
u
only be carried out by qualified electri-
cians.
Observe and comply with the respective
u
national regulations (in Germany VDE
0100 and others).
When laying the network connection
u
cable on-site, all-pole safety isolation
must be established.
Only carry out work when the power
u
supply is disconnected.
Subject to change.

Technical data

Roto Safe Eneo drive
Voltage
Continuous current
consumption
Current consumption
Relative air humidity
Temperature
Output relay load
Standards
Cable junction (on the sash side)
Max. voltage
Max. current
Line
Line length on the connector
side
Degree of protection in
accordance with DIN 40050
Temperature when idle
Cores
Power supply unit
DC voltage
Rated current
Voltage adjustment range
Voltage range
Frequency range
Temperature
Relative air humidity
INFO
If a different power supply unit is used,
ensure that it has 24 V and 2.5 A at the
output (see SUG_3).
Roto Safe Eneo
24 V DC (±5%), 2.5 A, SELV output voltage
according to EN 60950-1
25 mA
1.5 A (peak 2.3 A)
≤ 93%
–25 to +60 °C (transport –25 to +70 °C)
Max. 40 mA, flyback diode for inductive load
present internally
EN 60 730-1,
EN 50090-2-2
Low Voltage Directive complied with,
CE conformity
48 V DC
3 A
LiF9Y11Y, six-pole version,
Ø 4.9 mm, grey
4 m
IP67 (when inserted)
–40 to +75 °C
(transport –5 to +50 °C)
0.34 mm
2
(white, green, brown,
yellow, pink, grey)
24 V (output)
2.5 A (output)
21.6 to 26.4 A (output)
88 to 264 V AC, 124 to 370 V DC (input)
47 to 63 Hz (input)
–20 to +60 °C
20% to 93%
SUG_11_EN_v0 · 04 / 2019 · 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Safe Eneo Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Roto Safe Eneo Series

  • Page 1 The complete documentation for this extract is as Standards EN 60 730-1, follows: EN 50090-2-2 Roto Safe Eneo installation instructions: ■ Low Voltage Directive complied with, C | CC | CF: IMO_438 CE conformity Control Unit: IMO_288 Roto Safe Eneo brief instructions: ■...
  • Page 2 Roto Safe Eneo Connection diagram Roto Safe Eneo A and AF Eneo A / AF Eneo A / AF green grün plug / cable assignment Stecker- / Kabelbelegung white: IN1 / Input 1 (open) weiß: IN1 / Eingang 1 (AUF)
  • Page 3 Roto Safe Eneo Roto Safe Eneo C, CC and CF Eneo C / CC / CF Eneo C / CC / CF schwarz grün green black Stecker- / Kabelbelegung plug / cable assignment weiß: IN1 / Eingang 1 (AUF) white: IN1 / Input 1 (open)
  • Page 4 INFO Initial operation Roto Safe Eneo C and CF Before connecting Roto Safe Eneo to the supply voltage, A pull handle or rod handle must be fitted to the outside of the door. check that it is working properly, as for a mechanical multipoint locking system.
  • Page 5 Multipoint locking system was actuated by When a door has been unlocked manually, it must cylinder. also be locked again manually. Roto Safe Eneo does not lock fully (with Door or strikers not set correctly (3x two-tone Adjust the door or strikers. fault message).
  • Page 6 Roto Safe Eneo Acoustic signals Sound Message Meaning Corrective action 1x beep Confirmation Command understood, process completed correctly. 3x short beeps Note Command understood but cannot be executed because the Multipoint locking system was actuated too often in maximum number of cycles in the time unit has been a short time period.
  • Page 7 Roto Safe Eneo Declaration of Conformity Eneo AF Eneo CF 0757 0757 Roto-Frank Austria GmbH Roto-Frank Austria GmbH Lapp-Finze-Str. 21 Lapp-Finze-Str. 21 A-8401 Kalsdorf bei Graz A-8401 Kalsdorf bei Graz Austria Austria Notausgangsverschluss lt. EN179 - E601 Notausgangsverschluss lt. EN179 - E611 LE/DoP-Nr.

This manual is also suitable for:

Safe eneo aSafe eneo afSafe eneo cSafe eneo ccSafe eneo cf

Table of Contents