SAFEMATIC MULTILUBE Troubleshooting page 4

Advertisement

1.3 A lubrication point gets too little lubricant or nothing at all
Operation disturbance
The rotation of the bearing makes
noise, is trembling or the
temperature is rising.
Doser does not operate
Grease leakage in the area of
lubrication piping.
1.4 A lubrication point gets too much lubricant
Operation disturbance
Considerable grease leakage in
the lubrication point.
The temperature of the bearing
rises.
2 WARNINGS
Caution
Note
3 CONTACT INFORMATION
Oy SKF Ab
P.O. BOX 80
40951 MUURAME
FINLAND
Tel. +358 14 600 611
Fax. +358 14 600 600
WWW: www.SKF.com
HTRB2AEN.doc
Cause of operation disturbance
The dosage adjustment of the
doser is too small.
The lubrication point has clogged.
Lubrication pipe or hose has
clogged.
The doser is damaged.
Lubrication piping between the
doser and lubrication point is
damaged.
Cause of operation disturbance
The dosage adjustment of the
doser is too large.
The doser is damaged.
The lubrication disturbances of the critical lubrication points must be repaired
immediately, since inadequate lubrication rapidly damages the equipment or
machinery being lubricated.
In the event that the operation disturbance can not be repaired with the help of
these instructions, please contact the supplier immediately.
MULTILUBE
TROUBLESHOOTING
Solution
Increase the dosage.
Clean the lubrication point.
Clean or replace lubrication pipe
or hose.
Replace the doser.
Check and repair the lubrication
piping.
Solution
Adjust the dosage to a smaller
amount.
Replace the doser.
3 (3)
23.08.2006 Rev. 2A