Download Print this page

Advertisement

Quick Links

MULTILUBE – SYSTEM TROUBLESHOOTING
TABLE OF CONTENTS
1 SYSTEM TROUBLESHOOTING.......................................................................................................................1
1.1 Control unit does not operate......................................................................................................................1
1.1.1 User interface does not operate...........................................................................................................1
1.1.2 Control center does not operate...........................................................................................................1
1.2 Control unit triggers an alarm......................................................................................................................1
1.2.1 User interface triggers an alarm...........................................................................................................1
1.2.2 Control center triggers an alarm...........................................................................................................2
1.3 A lubrication point gets too little lubricant or nothing at all..........................................................................3
1.4 A lubrication point gets too much lubricant .................................................................................................3
2 WARNINGS .......................................................................................................................................................3
3 CONTACT INFORMATION ...............................................................................................................................3
HTRB2AEN.doc
MULTILUBE
TROUBLESHOOTING
23.08.2006 Rev. 2A

Advertisement

loading

Summary of Contents for SAFEMATIC MULTILUBE

  • Page 1 MULTILUBE TROUBLESHOOTING MULTILUBE – SYSTEM TROUBLESHOOTING TABLE OF CONTENTS 1 SYSTEM TROUBLESHOOTING........................1 1.1 Control unit does not operate........................1 1.1.1 User interface does not operate......................1 1.1.2 Control center does not operate......................1 1.2 Control unit triggers an alarm........................1 1.2.1 User interface triggers an alarm......................1 1.2.2 Control center triggers an alarm......................2...
  • Page 2 1 (3) MULTILUBE TROUBLESHOOTING MULTILUBE – SYSTEM TROUBLESHOOTING 1 SYSTEM TROUBLESHOOTING 1.1 Control unit does not operate 1.1.1 User interface does not operate Operation disturbance Cause of operation disturbance Solution Check supply voltage. Display and LED signals of user No supply voltage on pumping interface are not lit.
  • Page 3 2 (3) MULTILUBE TROUBLESHOOTING The red LED-signal for line is The lubricant has stiffened in the Set lubrication cycle longer or blinking at the user interface. piping because of the operating change the lubricant for an Alarm, high pressure on display.
  • Page 4 3 (3) MULTILUBE TROUBLESHOOTING 1.3 A lubrication point gets too little lubricant or nothing at all Operation disturbance Cause of operation disturbance Solution The rotation of the bearing makes The dosage adjustment of the Increase the dosage. noise, is trembling or the doser is too small.