NewMar PE Series Installation & Operation Manual

NewMar PE Series Installation & Operation Manual

Annunciator panel, universal bbu annunciator

Advertisement

Quick Links

Installation/Operation Manual
15272 Newsboy Circle
Huntington Beach
California 92649
PE Series
Annunciator Panel
Universal BBU Annunciator
Model: AP-8000A
Section
Safety Information........................................... 1
General Information........................................ 1
Installation and Wiring................................... 1
Specifications................................................... 4
Regulatory Information................................... 5
Troubleshooting..............................................
Limited Warranty............................................. 5
Circuit Board Illustration.................................. 6
Wiring Diagram............................................... 7
PoweringTheNetwork.com
Page
5
Phone: 714-751-0488
E-Mail: techservice@newmarpower.com
M-AP8000A
As of 012720
Fax: 714-896-9679

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for NewMar PE Series

  • Page 1 PE Series Annunciator Panel Universal BBU Annunciator Installation/Operation Manual Model: AP-8000A Section Page Safety Information........... 1 General Information........1 Installation and Wiring........1 Summary Alarm Option (Auto Dialer).... 3 Programming and RS-485 Features....3 Specifications........... 4 Regulatory Information........5 Troubleshooting..........
  • Page 2 Safety Information FOR COMMERCIAL USE ONLY CAUTION Up to 60 Volts DC may be present on the terminals. DO NOT SHORT ACROSS THE POWER SUPPLY TERMINALS • Keep fingers and all metal objects from power terminals and wires. • Use insulated hand tools. •...
  • Page 3 2. The AP-8000A is designed to be wall mounted. Select a suitable location in accordance with any approved building plans or as specified by the Authority Having Jurisdiction. 3. Affix the cabinet to the wall using the supplied hardware. If required, alternative mounting arrangements may be used but avoid drilling new holes in the front cover door.. B) Wiring The following wiring is required to place the annunciator into service: 1) Connection to a power supply: See wiring diagram on page 7.
  • Page 4 Each Form-C alarm output relay has a separate wiring terminal. These terminals are located along the right-hand side of the circuit board with “Alarm 1” at the top, and “Alarm 8” at the bottom. The alarm relay terminals accept wire sizes 18-22 AWG. End Of Line Resistors: If desired, an in-series “End of Line”...
  • Page 5 RS-485 Pinout: • Pin -1: RS485A • Pin -2: RS485B • Pin -3: Ground • Pin -4: PoE+ (Not Used) • Pin -5: PoE+ (Not Used) • Pin -6: Ground • Pin -7: PoE- (Not Used) • Pin -8: PoE- (Not Used) RS-485 LED Indicators: •...
  • Page 6 Limited Warranty Newmar warrants that the AP-8000A PE Series Annunciator Panel to be free from defects in material and workmanship for two years from date of purchase. If a problem with your AP-8000A or if you have any questions about the installation and proper operation of the unit, please contact NEWMAR’s Technical Services Department:...
  • Page 7 Figure 2: Circuit Board Illustration Default DIP Switch Positions POS 1, 2: On POS 3, 4: Off Alarm LEDs (8) Power On Indicator EXPANSION Micro-processor PORT LED 12 Function Indicator POWER FAILURE 2 3 4 Addressing DIP Switch POS 1- 4: Off LED 9 BATTERY RESET...
  • Page 8 AC Fail OUTPUT: 48Vdc 10A techservice@newmarpower.com AC/L “+” Www.automationdcpower.com Relay 1 Relay 2 Relay 3 Newport Beach, CA USA NEWMAR Relay Repeater JUMPER FOR BATTERY 963-5983-0 Rev B 115 Vac AC Fail/On Batt Back-Up Low or Replace Battery Rectifier Fail ALARM...

This manual is also suitable for:

Ap-8000aAp-8000

Table of Contents