Download Print this page

Technical Characteristics - Pepperl+Fuchs KCT1-6WR/RS232-V Manual

Electronic preset counter

Advertisement

Available languages

Available languages

7. Connections
7.1 Terminal assignment X1
Supply voltage and outputs
Terminal No AC version
1
Output 1 – Relay contact
2
Output 1 – Relay contact
3
Output 2
Common relay contact (C)
4
Output 2 Relay
Closing contact (NO)
5
Output 2 Relay
Opening contact (NC)
6
Supply voltage
90..250 VAC
7
Supply voltage
90..250 VAC
Attention: In case of a
(reversed relay control), the connections of terminals 4
and 5 are reversed:
Terminal No AC versions
4
Opening contact relay (NC)
5
Closing contact relay ( NO)
7.2 Terminal assignment X2
Inputs
Terminal Designation AC version
No.
1
+24 VDC
Sensor supply
voltage
2
0 VDC
Reference voltage
(GND)
3
INP A
Counting input A
4
INP B
Counting input B
5
RESET
Reset input
6
GATE
GATE input
7
KEY
Push-button locking input
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Serial interface
and a
setting

8. Technical characteristics

Supply voltage:
90..250 VAC, 5VA max.
Display:
6 digits, red 7-segment
LED's, display height 8 mm
Polarity of the input signals:
programmable in common for
all inputs (npn or pnp).
Input resistance: approximately. 10 kW
Counting frequency:
20 kHz (10 kHz with phase
discriminator), can be reduced to
30 Hz. In case of automatic
repetition, 1.2 kHz without loss of
pulses (700 Hz with phase
discriminator and pulse multiplication
by 2).
Minimum pulse duration for control inputs:
5 ms
Input switching level:
With AC supply voltage:
log."0": 0..4 VDC
log."1":12..30 VDC
With DC supply voltage:
log."0": 0..0,2 x U
log."1": 0,6 x U
Pulse shape:
any shape (Schmitt trigger inputs)
Accuracy in the frequency meter/speed indicator mode:
< 0,1 %
Accuracy in the time counter / operating time counter
mode:
± 50 ppm
Output 1:
Relay with potential-free
make or break contact,
programmable as opening or closing
contact.
Switching voltage max. 250 VAC /
125 VDC. Switching current max. 3A
Switching current min. 30 mA DC
Switching power 90 W /750 VA
Output 2:
Relay with potential-free change-over
contact, programmable as
opening or closing contact.
Switching voltage max. 250 VAC /
300 VDC.
Switching current max. 3A
Switching current min. 30 mA DC
Switching power 50 W / 2000 VA
Copyright Pepperl+Fuchs, Printed in Germany
B
..30 V DC
B
15

Advertisement